6.2 "H--" Error indication
‧
If there is an operation error, or if there is a problem with the washing machine,
(1)All the switchs can not be operated.
(2)An error indication will be displayed.
Indication
Method to clear
H01
The PS switch is abnormal.
*Pull out the power plug .
H09
*Pull out the power plug .
H55
*Malfuntion of over current of
inverter circuit.
*In case if overcurrent(above 10A)flow to the
inverter circuit,replace the PCB(Power side).
*Check if short circuit of the motor's coil,
replace the motor.
*Pull out the power plug .
H57
*Malfuntion of motor's current.
*Check if movement of the motor,
and replace the motor.
*Pull out the power plug .
*Pull out the power plug .
H52
*Malfuntion of high voltage.
*In case the input voltage to the PCB has been
detected over AC 150V,check input voltage
by test meter.
*Indicate 5 sec and auto power off.
*Pull out the power plug .
H53
*Malfuntion of low voltage.
*In case the input voltage to the PCB has been
detected below AC 65V,check input voltage
by test meter.
*Pull out the power plug .
*Check if you condition of the connectors.
*Replace the PS switch .
*Replace PCB board(Power side)
*Check if you condition of the power sw.
*Replace PCB board(Power side)
*Check if lead wire condition of P.C.
Boards between power and operation
side, and replace one of P.C. Board's.
H51
*Malfuntion of over load.
*Check if over load of laundry.
*Check if condition of connectors for motor
and rotary detector,necessary adjustment.
*Check if movement of the motor,replace it.
*Check if output voltage of the PCB(Power side)
,replace the PCB.
H25
The Motorized Drain Valve
(For draining water) is abnormal.
*In case the motorized drain valve won't operate
within 20 sec, after drain mode has started.
*Check if condition of connectors for motorized
drain valve, replace the motorized drain valve
*Check output voltage of the PCB(Power side)
and replace the PCB.
H21
*Pull out the power plug .
Check point
Content
The memory circuit of the I.C is
abnormal.
*Replace PCB board(Power side)
Open circuit of P.C. Board's
communication line.
H04
The power sw circuit is abnormal.
H05
*Pull out the power plug .
H07
*Malfuntion of over flow.
*Clean the diaphragm inside of the feed valve
or replace the the feed valve.
*Check output voltage of the PCB(Power side)
*Operate motorized drain valve and drain water
*Pull out the power plug .
*Pull out the power plug .
The rotary detector is abnormal.
*Check if condition of connectors for rotary
detector and leadwires
*Movement of the mechanism motor
*Replace PCB board(Power side)
*Pull out the power plug .
-9-