No. SX-DSV03089 -76-
R8.0
Motion Control
Business Unit, Panasonic Corporation
9. Compliance with global standards
9-1 Conforming standards
European EU
directive
EMC directive
EN 55011:2009/A1:2010 (Group 1, Class A)
EN61000-6-2
EN61000-6-4
EN 61800-3:2004/A1:2012 (Category C3, Second environment)
Low voltage directive
EN61800-5-1
EN50178
Machinery directive
Functional Safety
ISO13849-1
EN61508
EN62061
EN61800-5-2
IEC61326-3-1
IEC60204-1
UL standard
UL61800-5-1 (File No. E164620)
CSA standard
C22. 2 No. 274
KC
KN11
KN61000-4-2,3,4,5,6,8,11
IEC : International Electrotechnical Commission
EN
: Europaischen Norman
EMC : Electromagnetic Compatibility
UL
: Under writers Laboratoris
CSA : Canadian Standards Association
KC
: Radio Waves Act(South Korea)
The parameter of functional safety
With diagnosis of “EDM output”
Without diagnosis of “EDM output”
Safety Integrity Level
EN61508(SIL3)
EN62061(SILCL3)
EN61508(SIL2)
EN62061(SILCL2)
Performance Level
ISO13849-1 PL e (Cat.3)
ISO13849-1 PL d (Cat.3)
Safety Function
EN61800-5-2 (SIL 3, STO)
EN61800-5-2 (SIL 2, STO)
Probability of dangerous failure <For size A,B,C,D,E,F>
PFH = 1.34 ×10
-8
(%SIL3=13.4%)
<For size G and H>
PFH = 1.78 ×10
-8
(%SIL3=17.8%)
<For size A,B,C,D,E,F>
PFH = 1.40 ×10
-8
(%SIL2=1.40%)
<For size G and H>
PFH = 1.85 ×10
-8
(%SIL2=1.85%)
Mean time to dangerous failure
MTTFd : High (100 years)
MTTFd : High (100 years)
Average diagnostic coverage
DC : Medium
DC : Low
Mission time
15 years
15 years