No. SX-DSV03089 -70-
R8.0
Motion Control
Business Unit, Panasonic Corporation
Connection of a battery for the absolute encoder
Connect a battery for the absolute encoder directly between BAT+ and BAT- of the encoder connector on the motor side.
Or, it is also possible to connect the battery to the terminals 14 and 15 of the X4 , and then connect through the
terminals 3 and 4 of the X6 .
Motor
Encoder cable
Servo driver
BAT+
BAT-
BTP-I
Shell
(
FG
)
X6
3
4
14
15
Battery
BTP-O
BTN-O
FG
X4
BTN-I
Note: If the battery is directly connected to the encoder connectors at the motor, do not connect any wire to the terminals 3
and 4 of the X6 .