background image

B51

B50

English

After-Sale Service (Repair)

  

Repair

Consult to a dealer from whom you have purchased the product for details of repair.

When the product is incorporated to the machine or equipment you have purchased,

consult to the manufacturer or the dealer of the machine or equipment.

Cautions for Proper Use

 • Practical considerations for exporting the product or assembly containing the product

   When the end user of the product or end use of the product is associated with mili-

tary affair or weapon, its export may be controlled by the Foreign Exchange and 

Foreign Trade Control Law. Complete review of the product to be exported and ex-

port formalities should be practiced.

 • This product is intended to be used with a general industrial product, but not de-

signed or manufactured to be used in a machine or system that may cause personal 

death when it is failed.

 • Installation, wiring, operation, maintenance, etc., of the equipment should be done 

by qualified and experienced personnel.

 • Apply adequate tightening torque to the product mounting screw by taking into 

consideration strength of the screw and the characteristics of material to which the 

product is installed. Overtightening can damage the screw and/or material; under-

tightening can result in loosening.

  Example) Steel screw (M5) into steel section: 2.7-3.3 N·m.

 • Install a safety equipments or apparatus in your application, when  a serious acci-

dent or loss of property is expected due to the failure of this product.

 • Consult us if the application of this product is under such special conditions and envi-

ronments as nuclear energy control, aerospace, transportation, medical equipment, 

various safety equipments or equipments which require a lesser air contamination.

 • We have been making the best effort to ensure the highest quality of the products, 

however, application of exceptionally larger external noise disturbance and static 

electricity, or failure in input power, wiring and components may result in unexpected 

action. It is highly recommended that you make a fail-safe design and secure the 

safety in the operative range.

 • If the motor shaft is not electrically grounded, it may cause an electrolytic corrosion 

to the bearing, depending on the condition of the machine and its mounting environ-

ment, and may result in the bearing noise. Checking and verification by customer is 

required.

 • Failure of this product depending on its content, may generate smoke of about one 

cigarette. Take this into consideration when the application of the machine is clean 

room related.

 • Please be careful when using in an environment with high concentrations of sulfur 

or sulfric gases, as sulfuration can lead to disconnection from the chip resistor or a 

poor contact connection.

7-1-1 Morofuku, Daito, Osaka, 574-0044, Japan   Phone : +81-72-871-1212

© Panasonic Corporation 2009

 • Take care to avoid inputting a supply voltage which significantly exceeds the rated 

range to the power supply of this product. Failure to heed this caution may result in 

damage to the internal parts, causing smoking and/or a fire and other trouble.

 • The user is responsible for matching between machine and components in terms 

of configuration, dimensions, life expectancy, characteristics, when installing the 

machine or changing specification of the machine. The user is also responsible for 

complying with applicable laws and regulations.

 • The product will not be guaranteed when it is used outside its specification limits.

 • Parts are subject to minor change to improve performance.

Technical information

Technical information of this product (Operating Instructions, CAD data) can be 

downloaded from the following web site.

   http://industrial.panasonic.com/ww/i_e/25000/motor_fa_e/motor_fa_e.html

For your records:

The model number and serial number of this product can be found on either the back or the 

bottom of the unit. Please note them in the space provided and keep for future reference.

Model No.

M

D

       

M

M

       

Serial No.

Date of

purchase

Dealer

Name

Address

Phone

  (              )                       - 

Содержание MAD Series

Страница 1: ...brake B23 Wiring to the Connector X1 B24 Wiring to the Connector X4 B25 Wiring to the Connector X6 B27 Wiring to the Connector X7 B28 4 Parameter B29 Outline Setup Connection B29 Composition of Parameters B31 5 Protective Functions B32 Protective Function What Is Error Code B32 6 Maintenance and Inspections B34 7 Conformity to EC Directives and UL Standards B36 Composition of Peripheral Equipments...

Страница 2: ...For details inquire the dealer Symbol MSME 1 0 kW to 5 0 kW MDME MFME MGME MHME Symbol 1 2 2 M S M D 5 A Z G 1 S 1 to 4 5 to 6 11 to 12 7 8 9 10 Voltage specifications Low inertia 50 W to 750 W High inertia 200 W to 750 W Low inertia 50 W to 5 0 kW Middle inertia 1 0 kW to 5 0 kW Middle inertia 1 5 kW to 4 5 kW Middle inertia 900 W to 4 5 kW High inertia 1 0 kW to 5 0 kW G Incremental Resolution 5...

Страница 3: ...Reserve enough sur rounding space for effective cooling Install fans to provide uniform distribution of temperature in the control panel D E F frame is pro vided with a cooling fan at the bottom Observe the environ mental conditions of the control panel described in the previous page Fan Fan 100 mm or more 100 mm or more 40 mm or more 40 mm or more 10 mm or more 10 mm or more 10 mm or more Directi...

Страница 4: ...ired 2 Installation Motor 2 Installation Motor Install the motor properly to avoid a breakdown or an accident Installation Place Since the conditions of location affect a lot to the motor life select a place which meets the conditions below 1 Indoors where the products are not subjected to rain or direct sun beam The prod ucts are not waterproof 2 Where the products are not subjected to corrosive ...

Страница 5: ...nd B2 set up Pr0 16 to 1 or 2 Note that no regenerative resistor is equipped in Frame A and B type B1 Pin 6 B2 Pin 4 Note Mains Short circuit wire B2 B3 2 Ground terminal Junction cable for brake DC Power supply for brake DC24 V to be supplied by customer U phase red V phase white W phase black Charg lamp Red LED 1 1 Do not make displacement wiring or inspection while the LED is lit cause of elect...

Страница 6: ...enerative resistor between B1 and B2 set up Pr0 16 to 1 or 2 B1 Pin 6 B2 Pin 4 Mains These colors are used for optional cable Residual current device Apply the voltage designated on the nameplate from the power source Symmetric current should be 5000 Arms or below If the short circuit current on the power source exceeds this value use a current limiting device e g current limiting fuse current lim...

Страница 7: ...ct of the noise generated by the servo driver Magnetic Contactor MC Turns on off the main power of the servo driver Use coil surge suppression units together with this Never start nor stop the servo motor with this Magnetic Contactor Reactor L Reduces harmonic current of the main power Mains Residual current device Apply the voltage designated on the nameplate from the power source Symmetric curre...

Страница 8: ...conductive materials such as wire chips entering the driver during the installation and wiring Driver Applicable motor Voltage 1 Rated output Required Power at the rated load Circuit breaker rated current Noise filter Single phase 3 phase Surge absorber Single phase 3 phase Noise filter for signal Rated operating current of magnetic contactor Contact configuration Diameter and withstand voltage of...

Страница 9: ...r to P B14 L1C L3 L2 L1 L2C B1 B3 B2 U V W XA XB 2 3 4 5 1 2 3 4 5 6 1 DC power supply for brake External regenerative resistor These colors are used for optional cable Red Black Green or Green yellow White RCD Motor Varistor DC 24 V U V W E Fuse 125 V 10 A Check the name plate of the driver for power specifications Provide a residual current device The residual current device to be the one design...

Страница 10: ...he holding brake and how to use it refer to P B43 Specifications of Built in Holding Brake Provide a varistor Connect a 10 A fuse in series with the varistor Ground resistance 100 Ω max For applicable wire refer to P B14 DC power supply for brake Fuse 125 V 10 A Red Black Green White MCCB Power supply NF MC L RCD External regenerative resistor These colors are used for optional cable 3 System Conf...

Страница 11: ...ge suppression units ALM Red White Black Green or Green Yellow Red White Black Green or Green Yellow XA XB X4 L ON MC ALM OFF Built in thermostat of an external regenerative resistor light yellow MC Built in thermostat of an external regenerative resistor light yellow Main power supply Control power supply Motor connection Main power supply Control power supply Motor connection XA XB X4 When you u...

Страница 12: ...ll be shut off when an error occurs JN8AT04NJ1 1 U phase V phase W phase Ground PIN No 2 3 PE Application PE 3 2 1 1 2 Motor Brake JN4AT02PJ1 R Tightening torque of the screw M2 0 085 to 0 095 N m screwed to plastic Tightening torque of the screw M2 0 19 to 0 21 N m 1 2 Brake Brake PIN No Application Be sure to use only the screw supplied with the connector to avoid damage Do not connect anything ...

Страница 13: ... 1 kΩ1 2 W 2 kΩ1 2 W V DC 1 5 R 220 10 mA Servo ON input Gain switching input Electronic gear switching input 1 Control mode switching input Damping control switching input 1 Alarm clear input Positive direction over travel inhibition input Negative direction over travel inhibition input Servo Ready output Servo Alarm output Positioning complete output External brake release output Torque in limit...

Страница 14: ...Example of Internal Velocity Control Mode 3 System Configuration and Wiring Wiring to the connector X4 SP IM 1 kΩ 1 kΩ FG 50 43 42 X4 represents twisted pair A phase output B phase output Z phase output Velocity monitor output Torque monitor output 7 COM INH CL SRV ON GAIN DIV1 ZEROSPD C MODE A CLR POT NOT S RDY S RDY ALM AT SPEED BRKOFF BRKOFF TLC V DC 12 to 24 V ZSP COM AT SPEED ALM 33 30 29 27 ...

Страница 15: ...lay Press this to switch 4 kinds of mode 1 Monitor Mode 2 Parameter Set up Mode 3 EEPROM Write Mode 4 Auxiliary Function Mode SET Button valid at any time Press this to switch SELECTION and EXECUTION display 6 1 X7 3 System Configuration and Wiring Wiring to the connector X7 The connector X7 of the front panel is for monitor output Analogue output 2 systems In both cases it is possible to switch t...

Страница 16: ...the driver use commercially available USB mini B connector The connector on the personal computer side should be in accordance with the specifications of the PC When the cable does not have noise filter attach a signal line noise filter DV0P1460 to both ends of the cable 4 Parameter Outline Setup Connection Connect to X1 USB mini B Setup support software PANATERM Please download from our web site ...

Страница 17: ...sconnect error protection 1 Encoder communication error protection 23 0 Encoder communication data error protection 24 0 Position deviation excess protection 26 0 Over speed protection 1 2nd over speed protection 27 0 Command pulse input frequency error protection 2 Command pulse multiplier error protection 28 0 Limit of pulse replay error protection 29 0 Deviation counter overflow protection Erro...

Страница 18: ...Odor Lint or other particles at air holes Cleanness at front portion of the driver and connector Damage of the cables Loose connection or misalignment between the motor and machine or equipment Pinching of foreign object at the load Periodical inspection Annual Loose tightening Trace of overheat Damage to the terminal block Loose fasteners on terminal block Note Inspection cycle may change when th...

Страница 19: ... copper cable with temperature rating of 75 C or higher 3 Over load protection level Over load protective function will be activated when the effective current exceeds 115 or more than the rated current based on the time characteristics see the next page Confirm that the effective current of the driver does not exceed the rated current Set up the peak permissible current with Pr0 13 Setup of 1st t...

Страница 20: ...C12 to 24 V which has CE marking or complies with EN60950 Circuit Breaker Install a circuit breaker which complies with IEC Standards and UL recognized Listed and marked between power supply and noise filter Integral solid state short circuit protection does not provide branch circuit protection Branch circuit protection must be provided in accordance with the National Electrical Code and any addi...

Страница 21: ...tion of the load condition For the detailed specifications of each noise filter contact the manufacturer Surge Absorber Provide a surge absorber for the primary side of noise filter Option part No Voltage specifications for driver Manufacturer s part No Manufacturer DV0P1450 3 phase 200 V R A V 781BXZ 4 Okaya Electric Ind Circuit diagram 1 ø4 2 0 2 41 1 UL 1015 AWG16 28 1 5 5 1 11 1 28 5 1 4 5 0 5...

Страница 22: ...oil is energized brake is open Pay an extra attention when magnetic sensors are used nearby the motor Noise Filter for Signal Lines Install noise filters for signal lines to all cables power cable motor cable encoder cable and interface cable Optional parts 24 V Power cable Encoder cable Interface cable and USB cable Option part No Manufacturer s part No Manufacturer DV0P1460 ZCAT3035 1330 TDK Cor...

Страница 23: ...0 002 35 or less 20 or less 0 3 DC1 V or more 39 2 4 9 30000 200 W 400 W 1 27 or more 0 018 50 or less 15 or less 0 36 137 44 1 750 W 2 45 or more 0 075 70 or less 20 or less 0 42 196 147 MHMD 200 W 400 W 1 27 or more 0 018 50 or less 15 or less 0 36 DC1 V or more 137 44 1 30000 750 W 2 45 or more 0 075 70 or less 20 or less 0 42 196 147 MSME 1 0 kW 1 5 kW 2 0 kW 7 8 or more 0 33 50 or less 15 or ...

Страница 24: ...V MSME Low inertia 3000 r min MSME102G 1 0 kW MDD T5540E D frame MSME152G 1 5 kW 3 phase 200 V MSME202G 2 0 kW MED T7364E E frame MSME302G 3 0 kW MFD TA390E F frame MSME402G 4 0 kW MFD TB3A2E MSME502G 5 0 kW Motor Driver Power supply Type Rated rotational speed Model Rated output Model Frame Single 3 phase 200 V MDME Middle inertia 2000 r min MDME102G 1 0 kW MDD T3530E D frame MDME152G 1 5 kW MDD ...

Страница 25: ... enabled encoder pulses count is the max Protective function Hard error Over voltage under voltage over speed over load over heat over current and encoder error etc Soft error Excess position deviation command pulse division error EEPROM error etc Traceability of alarm data The alarm data history can be referred to 11 Specifications Basic Specifications Input power 100 V Main circuit Single phase ...

Страница 26: ...atic electricity or failure in input power wiring and components may result in unexpected action It is highly recommended that you make a fail safe design and secure the safety in the operative range If the motor shaft is not electrically grounded it may cause an electrolytic corrosion to the bearing depending on the condition of the machine and its mounting environ ment and may result in the bear...

Страница 27: ...IME03 B Z0110 3043 7 1 1 Morofuku Daito Osaka 574 0044 Japan Phone 81 72 871 1212 Panasonic Corporation 2009 Printed in China ...