52
5.2
Output Additional Information
5.2.1 Output the scanned data adding Code Reader’s individual name
It can be used for multi-configuration with the reader. Host computer can recognize
the data which reader has sent.
Set an individual name to each reader
MYNAME=aaaa
aaaa: (Alphanumeric strings from 1 to 31 digits)
The name of all Code Readers is “My Reader” in default setting. Make sure to set an
individual name to each Code Reader before using this function.
Configure to output individual name.
The output method is selectable by the connection with the host device.
NAMETX=a,b
a=0: No Code Reader name will be included on the reading
result (RS-232C)
1: Code Reader name will be included on the reading result
(RS-232C)
b= 0: No Code Reader name will be included on the reading result
(LAN)
1: Code Reader name will be included on the reading result
(LAN)
Skip b: Configure LAN same with RS-232C
5.2.2 Warning Information to avoid No Read
Add a Warning Information to the symbol data for monitoring the reading condition.
Output format: (CcccEeeeDddd)
ccc: Contrast Information for the captured image
eee: Unused Error Correction rate
ddd: Decodability margin
e.g.1) Good Read
Data Output: (C082E100D091)A123456A
Calculate contrast value of a symbol including quiet zone. The decoder
determines a rectangular area for the symbol and calculates the contrast value
from its brightness level. If there are multiple symbols, the calculated value is for
the first decoded symbol.
e.g.2) No Read
Data Output: (C000E000D000) BR