23
3 Operation Mode
LP-ABR has can be operated in following 2 modes.
Operational Mode
Command
Description
Single Reading Mode
SYNCMODE=0 Single read for each SYNC input.
Reading Timeout Mode
SYNCMODE=1 After SYNC input, the reader
continues reading during the duration
time set by “TOTALLIM”. The reader
sends an error code when it fails in
reading when the duration time
passes.
External Trigger Mode
SYNCMODE=2 The reader continues reading during
the SYNC input is active. It receives
no g command (start reading
command) .
"Read” includes capturing and decoding an image.
The Diagnostic Mode is available when the operation mode is in Single Reading
Mode.
Diagnostic Mode
Command
Description
Normal Mode
TEST=0
For normal use and to return to
Normal Mode
Test Mode
TEST=1
For measurement of reading rate of
symbols.
Continuous Reading Mode
continue
For camera adjustment. To release
the reader from Continuous Reading
Mode, send a “stop” command.
Diagnostic Mode is used to configure the reader. Do not use the Diagnostic Mode
in normal operation.