24
Timing Chart
DELAY:
The time from SYNC ON to reading.
CHATT:
The time needed for eliminating the chattering.
IMAGE:
The time duration for capturing an image.
DECODE:
The time duration for decoding.
DECODELIM:
The maximum time limit for decoding.
GOOUT:
The length of time the GO signal is asserted.
NGOUT:
The length of time the NG signal is asserted.
SERIAL:
The time the data is output through the serial interface.
MAXIMG:
The maximum number of images in the buffer.
WAITIMG:
The interval time between capturing images.
Soft Trigger:
The SYNC issued by serial command input.
Hard Trigger:
The SYNC issued by digital input or Read Key.
3.1
Single Reading Mode
Code Reader performs a single read for each SYNC input.
3.1.1 Soft trigger, Good Read, Data transmission: After decode
DELAY
SYNC
IMAGE
DECODE
SERIAL
GOOUT
GOOUT
DECODELIM
decode1
image1