LC2H

2. Backlight type

Notes) 1. Do not reverse the polarities when connecting the DC voltage for the backlight.

2.

2

 and 

4

. (The input and reset circuits are functionally insulated.)

3. When using transistor (Tr) input, use the right as a guide. (Collector withstand voltage 

Q

 50 V, leakage current < 1 µA)

4. Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal, and the application of voltage to the reset input 

terminal, can cause damage to the internal elements.

Explanation of operation

Voltage input type

Backlight connection

Contact input

Transistor input

NPN transistor

PNP transistor

Reset

input

Count

input

1

2

3

4

5

6

0V

0V

Reset

input

Count

input

1

2

3

4

+V

+V

5

6

1

2

3

4

5

6

Reset

input

Count

input

+V

+V

1

2

3

4

Green

Red

24V DC

24V DC

5

6

1

2

3

4

5

6

1. Counting takes place when the count 
input signal is ON.
2. Counting resumes again when the 
count value reaches 99999999 (full scale 
value) and then returns to “0” with a new 
count input.
3. No measurement takes place when a 
reset is input.
1) When reset is ON, resetting takes 
place and the count becomes “0”.
2) Press the front reset button when you 
want to reset manually (only panel 
installation type).

Note) Be aware that battery life will decrease if the 

count input or reset input are left ON.

             Note) 

Count becomes “1” when the reset input is turned OFF while the count signal is being input.

Reset input

Count value

Count input

0

1

0

0

1

1

99999999

All Rights Reserved © C

OPYRIGHT

 Matsushita Electric Works, Ltd.

Содержание LC4H-PS-R6-AC240V

Страница 1: ...at uses the bracket on the timer counter Choose a method that suits the application 5 Battery Replacement Easy on Environment To replace battery simply remove body for the one touch installation type and remove battery lid for the installation frame type 6 Screw Terminals Designed for Safety Built in finger protection 7 Panel Covers Replacable Standard color is ash gray Change the panel design by ...

Страница 2: ... Switchable by switch 30 Hz Note 2 Count input Min input signal width ON OFF 1 1 0 25 ms 16 7 ms Switchable by switch 16 7 ms Input method signal Non voltage input using contacts or open collector connection High level 4 5 to 30 V DC Low level 0 to 2 V DC High level 24 to 240 V AC DC Low level 0 to 2 4 V AC DC Input impedance When shorted Max 10 kΩ When open Max 750 kΩ Approx 4 7 kΩ Residual volta...

Страница 3: ... 1 1 0 25 ms 16 7 ms Input method Non voltage input using contacts or open collector connection Input impedance When shorted Max 10 kΩ When open Max 750 kΩ Residual voltage Max 0 5 V Reset input Min input signal width 10 ms Input method Non voltage input using contacts or open collector connection Input impedance When shorted Max 10 kΩ When open Max 750 kΩ Residual power Max 0 5 V Break down volta...

Страница 4: ...nput Lock switch Unit display 1 Count speed switch Unit display 2 Count speed switch Lock switch RESET COUNTER LC2H Front reset button Terminal block side LCD side OFF ON Terminal block side LCD side 2k Hz 30Hz Fixed at 30 Hz Dimensions 1 Panel mounting type External dimensions 1 One touch installation type mm inch General tolerance 1 0 039 Panel installation diagram Note When installing to a 4 5 ...

Страница 5: ...the mounting frame ATH3803 and the rubber packing ATH3804 Only installation frame type For connected installation sealed installation Only installation frame type Notes 1 Suitable installation panel thickness is 1 to 4 5 mm 039 to 177 inch 2 Waterproofing will be lost when installing repeatedly sealed installation 45 1 772 0 5 0 020 0 22 2 874 0 5 0 020 0 60 min 2 362 min 22 2 874 0 5 0 020 0 A 48...

Страница 6: ... type Contact input Transistor input NPN transistor PNP transistor 2 PC board mounting type External dimensions Terminal layout and wiring diagrams General tolerance 1 0 039 mm inch PC board pattern BOTTOM VIEW General tolerance 0 1 004 Note The AXS212811K is recommended as a compatible connection socket LC2H COUNTER 33 02 0 3 1 300 012 43 4 1 709 17 3 681 DIP switch 8 19 748 15 24 0 3 600 012 3 3...

Страница 7: ...unt input 1 2 3 4 5 6 0V 0V Reset input Count input 1 2 3 4 V V 5 6 1 2 3 4 5 6 Reset input Count input V V 1 2 3 4 Green Red 24V DC 24V DC 5 6 1 2 3 4 5 6 1 Counting takes place when the count input signal is ON 2 Counting resumes again when the count value reaches 99999999 full scale value and then returns to 0 with a new count input 3 No measurement takes place when a reset is input 1 When rese...

Страница 8: ...ctions might occur if the floating capacitance of these wires exceeds 500 pF 10 m 32 808 ft for parallel wires of 2 mm2 3 Free voltage input type 1 Use count input terminals 1 and 2 for free voltage input and reset terminals 3 and 4 for non voltage input 2 Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal and the application of volta...

Отзывы: