background image

LC2H

Part names

1. Front reset button

This button resets the count value. It 
does not work when the lock switch is 
ON. Be aware that battery life will 
decrease if this switch is used frequently.

2. Lock switch (Refer to chart on 
right.)

Disable the front reset button.

Note) Turn ON at the LCD side (reset disabled) and 

OFF at the terminal block side (reset enabled).

3. Count speed switch (Refer to chart 
on right.)

Use this switch to switch the count speed 
between 30 Hz and 2 kHz. (On the non-
voltage and voltage input types, 30 Hz is 
on the LCD side and 2 kHz is on the 
terminal block side. Fixed at 30 Hz for 
free voltage input type.)

Note) You must press the front reset button when you 

change the count speed switch setting.
Confirm, however, that the Lock Switch is OFF 
(front switches operable).

Notes) 1.

Default setting when shipped.

2. Make the switch setting before installing to panel.

Non-voltage input/voltage input

Free voltage input

Lock switch
(Unit display 1)

Count speed 
switch
(Unit display 2)

Count speed switch

Lock switch

RESET

COUNTER

LC2H

Front reset button

(Terminal block side)

(LCD side)

OFF

ON

(Terminal block side)

(LCD side)

2k Hz

30Hz

(Fixed at 30 Hz)

Dimensions

1. Panel mounting type
• External dimensions

1) One-touch installation type

mm 

inch

General tolerance: 

±

1.0 

±

.039

• Panel installation diagram

Note) When installing to a 4.5 mm 

.177 inch

 thick panel, remove the rubber spacer 

first.

When installing the one-touch installation type model, make sure 
that the installation spring does not pinch the rubber gasket.
To prevent the installation spring 
from pinching the rubber gasket:
1. Set the rubber gasket on both 
ends of the installation spring 
(left and right).
2. Confirm that the installation 
spring is not pinching the rubber 
gasket, and then insert and fix the 
installation spring in place from the 
rear of the timer unit.

44.8

1.764

54.4

2.142

5

.197

(44)

(1.732)

10.4

.409

7

.276

22

.866

48

1.890

24

.945

Reset button

COUNTER

LC2H

RESET

Rubber spacer

Panel (1 to 4.5mm

.039 to .177inch

thickness)

All Rights Reserved © C

OPYRIGHT

 Matsushita Electric Works, Ltd.

Содержание LC4H-PS-R6-AC240V

Страница 1: ...at uses the bracket on the timer counter Choose a method that suits the application 5 Battery Replacement Easy on Environment To replace battery simply remove body for the one touch installation type and remove battery lid for the installation frame type 6 Screw Terminals Designed for Safety Built in finger protection 7 Panel Covers Replacable Standard color is ash gray Change the panel design by ...

Страница 2: ... Switchable by switch 30 Hz Note 2 Count input Min input signal width ON OFF 1 1 0 25 ms 16 7 ms Switchable by switch 16 7 ms Input method signal Non voltage input using contacts or open collector connection High level 4 5 to 30 V DC Low level 0 to 2 V DC High level 24 to 240 V AC DC Low level 0 to 2 4 V AC DC Input impedance When shorted Max 10 kΩ When open Max 750 kΩ Approx 4 7 kΩ Residual volta...

Страница 3: ... 1 1 0 25 ms 16 7 ms Input method Non voltage input using contacts or open collector connection Input impedance When shorted Max 10 kΩ When open Max 750 kΩ Residual voltage Max 0 5 V Reset input Min input signal width 10 ms Input method Non voltage input using contacts or open collector connection Input impedance When shorted Max 10 kΩ When open Max 750 kΩ Residual power Max 0 5 V Break down volta...

Страница 4: ...nput Lock switch Unit display 1 Count speed switch Unit display 2 Count speed switch Lock switch RESET COUNTER LC2H Front reset button Terminal block side LCD side OFF ON Terminal block side LCD side 2k Hz 30Hz Fixed at 30 Hz Dimensions 1 Panel mounting type External dimensions 1 One touch installation type mm inch General tolerance 1 0 039 Panel installation diagram Note When installing to a 4 5 ...

Страница 5: ...the mounting frame ATH3803 and the rubber packing ATH3804 Only installation frame type For connected installation sealed installation Only installation frame type Notes 1 Suitable installation panel thickness is 1 to 4 5 mm 039 to 177 inch 2 Waterproofing will be lost when installing repeatedly sealed installation 45 1 772 0 5 0 020 0 22 2 874 0 5 0 020 0 60 min 2 362 min 22 2 874 0 5 0 020 0 A 48...

Страница 6: ... type Contact input Transistor input NPN transistor PNP transistor 2 PC board mounting type External dimensions Terminal layout and wiring diagrams General tolerance 1 0 039 mm inch PC board pattern BOTTOM VIEW General tolerance 0 1 004 Note The AXS212811K is recommended as a compatible connection socket LC2H COUNTER 33 02 0 3 1 300 012 43 4 1 709 17 3 681 DIP switch 8 19 748 15 24 0 3 600 012 3 3...

Страница 7: ...unt input 1 2 3 4 5 6 0V 0V Reset input Count input 1 2 3 4 V V 5 6 1 2 3 4 5 6 Reset input Count input V V 1 2 3 4 Green Red 24V DC 24V DC 5 6 1 2 3 4 5 6 1 Counting takes place when the count input signal is ON 2 Counting resumes again when the count value reaches 99999999 full scale value and then returns to 0 with a new count input 3 No measurement takes place when a reset is input 1 When rese...

Страница 8: ...ctions might occur if the floating capacitance of these wires exceeds 500 pF 10 m 32 808 ft for parallel wires of 2 mm2 3 Free voltage input type 1 Use count input terminals 1 and 2 for free voltage input and reset terminals 3 and 4 for non voltage input 2 Be aware that the application of voltage that exceeds the voltage range of the H level to the count input terminal and the application of volta...

Отзывы: