To prevent the designated character sequence being altered by chance, it is recommended that the
configuration file starts with the comment line shown below:
# Panasonic SIP Phone Standard Format File # DO NOT CHANGE THIS LINE!
•
Configuration files must end with an empty line.
•
Each parameter line is written in the form of XXX="yyy" (XXX: parameter name, yyy: parameter value).
The value must be enclosed by double quotation marks.
•
A parameter line written over multiple lines is not allowed. It will cause an error on the configuration file,
resulting in invalid provisioning.
Configuration Parameters
•
The unit supports 6 telephone lines. For some parameters, the value for each line must be specified
independently. A parameter name with the suffix "
_1
" is the parameter for line 1; "
_2
" for line 2, and so on.
Examples of setting the line (phone number) for accessing a voice mail server:
"
VM_NUMBER_1
": for line 1,
"
VM_NUMBER_2
": for line 2, …,
"
VM_NUMBER_6
": for line 6
•
The maximum length of a parameter name is 32 characters.
•
The maximum length of a parameter value is 500 characters excluding double quotation marks.
•
No space characters are allowed in the line except when the value includes a space character(s).
Example:
DISPLAY_NAME_1="John Smith"
(valid)
DISPLAY_NAME_1 = "John Smith"
(invalid)
•
Some parameter values can be specified as "empty" to set the parameter values to empty.
Example:
SYSLOG_ADDR=""
•
The parameters have no order.
•
If the same parameter is specified in a configuration file more than once, the value specified first is applied.
•
All configurable settings can be specified in the configuration file. You can ignore settings that already have
the desired values. Only change parameters as necessary.
5.2.2 Configuration File Parameters
The information on each parameter that can be written in a configuration file is shown in the tables starting
from
. The information includes parameter name (as the title of the table), value format,
description, permitted value range, default value of each parameter, and Web user interface reference.
Parameter Name
This is the system-predefined parameter name and cannot be changed.
Note
•
Certain parameter names end with "
_n
". This signifies that these settings can be made to each line
individually. The unit supports 6 telephone lines.
Value Format
Each parameter value is categorized into Integer, Boolean, or String. Some parameters require a composite
form such as "Comma-separated Integer" or "Comma-separated String".
•
Integer
: a numerical value, described as a sequence of numerical characters, optionally preceded by a
"-" (minus)
An empty string is not allowed.
136
Administrator Guide
Document Version 2012-07
Section 5 Configuration File Programming
Содержание KX-UT670
Страница 14: ...14 Administrator Guide Document Version 2012 07 Table of Contents ...
Страница 226: ...226 Administrator Guide Document Version 2012 07 Section 8 Backup and Restore ...
Страница 230: ...230 Administrator Guide Document Version 2012 07 Section 9 Resetting the Unit ...
Страница 236: ...236 Administrator Guide Document Version 2012 07 Section 10 Troubleshooting ...
Страница 239: ...Section 12 Appendix Document Version 2012 07 Administrator Guide 239 ...
Страница 242: ...242 Administrator Guide Document Version 2012 07 Section 12 Appendix ...
Страница 243: ...Index Document Version 2012 07 Administrator Guide 243 ...
Страница 249: ...Document Version 2012 07 Administrator Guide 249 Notes ...