Default Value
5000
Web User Interface Reference
SIP_TIMER_F_n
Parameter Name Example
SIP_TIMER_F_1
,
SIP_TIMER_F_2
, …,
SIP_TIMER_F_6
Value Format
Integer
Description
Specifies the value of SIP timer F (non-INVITE transaction timeout
timer), in milliseconds. For details, refer to RFC 3261.
Value Range
250–64000
Default Value
32000
Web User Interface Reference
SIP_TIMER_H_n
Parameter Name Example
SIP_TIMER_H_1
,
SIP_TIMER_H_2
, …,
SIP_TIMER_H_6
Value Format
Integer
Description
Specifies the value of SIP timer H (wait time for ACK reception), in
milliseconds. For details, refer to RFC 3261.
Value Range
250–64000
Default Value
32000
Web User Interface Reference
SIP_TIMER_J_n
Parameter Name Example
SIP_TIMER_J_1
,
SIP_TIMER_J_2
, …,
SIP_TIMER_J_6
Value Format
Integer
Description
Specifies the value of SIP timer J (wait time for non-INVITE request
resending), in milliseconds. For details, refer to RFC 3261.
Value Range
0, 250–64000
Default Value
5000
Web User Interface Reference
ADD_TRANSPORT_UDP_n
Parameter Name Example
ADD_TRANSPORT_UDP_1
,
ADD_TRANSPORT_UDP_2
, …,
ADD_TRANSPORT_UDP_6
Value Format
Boolean
208
Administrator Guide
Document Version 2012-07
Section 5 Configuration File Programming
Содержание KX-UT670
Страница 14: ...14 Administrator Guide Document Version 2012 07 Table of Contents ...
Страница 226: ...226 Administrator Guide Document Version 2012 07 Section 8 Backup and Restore ...
Страница 230: ...230 Administrator Guide Document Version 2012 07 Section 9 Resetting the Unit ...
Страница 236: ...236 Administrator Guide Document Version 2012 07 Section 10 Troubleshooting ...
Страница 239: ...Section 12 Appendix Document Version 2012 07 Administrator Guide 239 ...
Страница 242: ...242 Administrator Guide Document Version 2012 07 Section 12 Appendix ...
Страница 243: ...Index Document Version 2012 07 Administrator Guide 243 ...
Страница 249: ...Document Version 2012 07 Administrator Guide 249 Notes ...