2.9 [3] Group
PC Programming Manual
367
Maintenance Console Location
2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
Programming Manual References
2.8.5 [2-4] Week Table
Feature Manual References
1.9.5 ICD Group Features—Overflow
1.9.6 ICD Group Features—Queuing
Time out & Manual Queue Redirection—Overflow Time
Specifies the length of time calls wait in a queue before they are redirected to the overflow destination.
Default
None
Value Range
None, 10 × n (n=1–125) s
Maintenance Console Location
2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
Programming Manual References
None
Feature Manual References
1.9.5 ICD Group Features—Overflow
1.9.6 ICD Group Features—Queuing
Hurry-up Level
Specifies the number of calls to hold in the queue before prompting Manual Queue Redirection by
flashing the Hurry-up button.
Default
None
Value Range
None, 1–30
Maintenance Console Location
2.9.9 [3-5-1] Incoming Call Distribution Group—Group Settings
Programming Manual References
2.10.5 [4-1-4] Wired Extension—Flexible Button
2.10.13 [4-2-3] Portable Station—Flexible Button