2.7 [1] Configuration
PC Programming Manual
169
Programming Manual References
None
Feature Manual References
None
Pulse Dial—Minimum MAKE Width
Specifies the minimum length of the make signal in a pulse dial.
Default
8 ms
Value Range
8 × n (n=1–5) ms
Maintenance Console Location
2.7.16 [1-1] Slot—T1 Card Property (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
Flash—Flash Signal Detection (OPX)
Enables the PBX to detect hookswitch flash signals from an SLT connected to an OPX.
Default
Enable
Value Range
Disable, Enable
Maintenance Console Location
2.7.16 [1-1] Slot—T1 Card Property (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
None
Flash—Minimum BREAK Width (OPX)
Specifies the minimum length of the break signal in a flash signal from an SLT connected to an OPX.