2.8 [2] System
PC Programming Manual
229
Value Range
1–15 s
Maintenance Console Location
2.8.4 [2-3] Timers & Counters
Programming Manual References
None
Feature Manual References
None
Dial—Analog CO Call Duration Start
Specifies the length of time between the end of dialing and the start of the SMDR timer for outgoing
analog CO line calls.
Default
0 s
Value Range
0–60 s
Maintenance Console Location
2.8.4 [2-3] Timers & Counters
Programming Manual References
None
Feature Manual References
1.16.1 SMDR (Station Message Detail Recording)
Intercept Routing No Answer (IRNA)—Day, Lunch, Break, Night
Specifies the length of time until an unanswered call is redirected to the intercept routing destination
in each time mode.
Note that this setting is only valid for extensions whose
Intercept No Answer Time—Day, Lunch,
Break, Night
is set to "0".
Default
40 s
Value Range
1–240 s
Maintenance Console Location
2.8.4 [2-3] Timers & Counters
Содержание KX-TDA50
Страница 9: ...PC Programming Manual 9 Section 1 Overview This section provides an overview of programming the PBX...
Страница 682: ...2 17 11 Maintenance 682 PC Programming Manual...
Страница 683: ...PC Programming Manual 683 Section 3 Appendix...
Страница 725: ...3 2 Feature Programming References PC Programming Manual 725...