1.4 Specifications
32
Installation Manual
Power Supply Unit Selection
Hybrid IP-PBX needs an optional power supply unit (PSU) suitable for its configuration. Calculate the load
figure from the type and number of items of equipment to be connected, and determine the type of PSU that
will be required.
Load Figure Calculation
PSU Capability
Each PSU supports a different amount of load figures.
Calculation Example (KX-TDA200)
Equipment Type
Load Figure
PT
KX-T7600 series DPT/DSS console
1
Other DPT/DSS console
4
APT
4
IP-PT
0
Extension Card
*1
*1
Only the extension cards that can support SLTs count for the load figures.
DHLC8
8
SLC8
8
SLC16
16
MSLC16
16
CS (1 unit)
4
PT-interface CS (1 unit)
4
VPS (1 port)
1
PSU Type
Maximum Load Figures
PSU-S
*1
*1
Available for the KX-TDA100
64
PSU-M
*2
*2
Available for the KX-TDA100 and KX-TDA200
128
PSU-L
*3
*3
Available for the KX-TDA200
512
Equipment Type
Load Figure
KX-T7600 series DPT
48 units
48
Other DPT
2 units
8
SLC16
1 card
16
MSLC16
1 card
16
VPS
8 ports
8
Содержание KX-TDA100 KX-TDA200
Страница 16: ...16 Installation Manual 5 1 Revision History 186 5 1 1 Version 1 1 186 5 1 2 Version 2 0 187 Index 189 ...
Страница 34: ...1 4 Specifications 34 Installation Manual ...
Страница 156: ...2 12 Starting the Hybrid IP PBX 156 Installation Manual ...
Страница 184: ...4 1 Troubleshooting 184 Installation Manual ...
Страница 185: ...Installation Manual 185 Section 5 Appendix ...
Страница 188: ...5 1 Revision History 188 Installation Manual ...
Страница 189: ...Installation Manual 189 Index ...
Страница 193: ...Index Installation Manual 193 ...