2.12 Starting the Hybrid IP-PBX
154
Installation Manual
2.
Plug the AC power cord into the Hybrid IP-PBX and an AC outlet, and turn on the Hybrid IP-PBX. The
RUN indicator will flash.
Note
For safety reasons, do not stretch, bend, or pinch the AC power cord.
3.
While the RUN indicator is flashing, return the System Initialize Switch to the "NORMAL" position.
Depending on the configuration, initialization takes about 1 min to 3 min. If successfully executed, the
RUN indicator will stop flashing and be kept lit.
All data will be cleared, and the Hybrid IP-PBX as well as all optional service cards (except for the IP-GW
card) will be initialized to the default values. The DPTs should show the time as 01:00.
The data of the IP-GW card will not be initialized.
Note
Use only the AC power cord included with the PSU.
LED Indications
Indication
Color
Description
RUN
Green
PBX status indication
•
OFF: Power off (includes normal reset)
•
ON: Power on and running (on-line)
•
Flashing (60 times per minute): Starting up
•
Flashing (120 times per minute): Starting up or resetting with:
•
the System Initialize Switch in "SYSTEM INITIALIZE"
position
•
the SD Memory Card not inserted
ALARM
Red
Alarm indication
•
OFF: Normal
•
ON: Alarm (CPU stop, alarm for each card)
•
Flashing: Alarm (MPR file error in restarting)
To AC Outlet
Содержание KX-TDA100 KX-TDA200
Страница 16: ...16 Installation Manual 5 1 Revision History 186 5 1 1 Version 1 1 186 5 1 2 Version 2 0 187 Index 189 ...
Страница 34: ...1 4 Specifications 34 Installation Manual ...
Страница 156: ...2 12 Starting the Hybrid IP PBX 156 Installation Manual ...
Страница 184: ...4 1 Troubleshooting 184 Installation Manual ...
Страница 185: ...Installation Manual 185 Section 5 Appendix ...
Страница 188: ...5 1 Revision History 188 Installation Manual ...
Страница 189: ...Installation Manual 189 Index ...
Страница 193: ...Index Installation Manual 193 ...