1.4 Specifications
Installation Manual
31
MEC Card Calculation
Calculate the MEC figure from the type and total number of items of equipment to be connected. If the MEC
figure exceeds 64 (for KX-TDA100) or 128 (for KX-TDA200), you need to install an MEC card.
MEC Card Calculation
Calculation Example (KX-TDA100)
The total MEC figure is 88. As this exceeds 64, you need to install an MEC card for this configuration.
External Sensor
8
16
External Relay
8
16
Add-on Key Module
64
128
128
256
USB Module
64
128
*1
A single "T1-OPX (Off Premise Extension) port" is counted as a wired telephone.
Equipment Type
MEC Figure
PT
KX-T7600 series DPT/DSS console
1
Other DPT/DSS console
1
APT
1
IP-PT
1
Extension Card
*1
*1
Only the extension cards that can support SLTs count for the MEC figures.
DHLC8
8
SLC8
8
SLC16
16
MSLC16
16
CS (1 unit)
0
PT-interface CS (1 unit)
0
VPS (1 port)
1
Equipment Type
MEC Figure
KX-T7600 series DPT
48 units
48
SLC16
1 card
16
MSLC16
1 card
16
VPS
8 ports
8
Total
88
Terminal Equipment Type
KX-TDA100
KX-TDA200
Without MEC
Card
With MEC
Card
Without MEC
Card
With MEC
Card
Содержание KX-TDA100 KX-TDA200
Страница 16: ...16 Installation Manual 5 1 Revision History 186 5 1 1 Version 1 1 186 5 1 2 Version 2 0 187 Index 189 ...
Страница 34: ...1 4 Specifications 34 Installation Manual ...
Страница 156: ...2 12 Starting the Hybrid IP PBX 156 Installation Manual ...
Страница 184: ...4 1 Troubleshooting 184 Installation Manual ...
Страница 185: ...Installation Manual 185 Section 5 Appendix ...
Страница 188: ...5 1 Revision History 188 Installation Manual ...
Страница 189: ...Installation Manual 189 Index ...