2.8 Connection of 2.4 GHz Portable Stations
134
Installation Manual
2.8.7
Connecting a Cell Station to the Hybrid IP-PBX
Using a CSIF Card
Refer to the following example to connect a CS to the Hybrid IP-PBX.
Accessory and User-supplied Items for the CS
Accessory (included):
Screws × 2, Washers × 2
User-supplied (not included):
RJ11 connector
Note
For details about CSIF card, refer to "2.5.1 CSIF4 and CSIF8 Card".
Signal Name
Signal Name
Pin No.
1
2
3
4
D1
POWH
POWL
D2
D1
POWH
POWL
D2
Pin No.
1
2
3
4
5
6
7
8
CSIF card (RJ45)
CS (RJ11)
Port 1
Cable
Maximum Distance
26 AWG:
Under 444 m (1457 ft)
24 AWG:
Under 694 m (2277 ft)
22 AWG:
Under 1000 m (3281 ft)
CAT 5:
Under 694 m (2277 ft)
CSIF8 Card