38
KX-NS500AG
11 Miscellaneous
11.1. How To Replace a Flat Package IC
Even if you do not have the special tools (for example, a spot heater) to remove the Flat IC, with some solder (large amount), a sol-
dering iron and a cutter knife, you can easily remove the ICs that have more than 100 pins.
11.1.1.
Preparation
• PbF (: Pb free) Solder
• Soldering Iron
Tip Temperature of 700
F ± 20
F (370
C ± 10
C)
Note:
We recommend a 30 to 40 Watt soldering iron. An
expert may be able to use a 60 to 80 Watt iron where some-
one with less experience could overheat and damage the
PCB foil.
• Flux
Recommended Flux: Specific Gravity
0.82.
Type
RMA (lower residue, non-cleaning type)
Note:
See
About Lead Free Solder (PbF: Pb free)
11.1.2.
Removal Procedure
1. Put plenty of solder on the IC pins so that the pins can be
completely covered.
Note:
If the IC pins are not soldered enough, you may give
pressure to the P.C. board when cutting the pins with
a cutter.
2. Make a few cuts into the joint (between the IC and its
pins) first and then cut off the pins thoroughly.
3. While the solder melts, remove it together with the IC
pins.
When you attach a new IC to the board, remove all solder
left on the land with some tools like a soldering wire. If some
solder is left at the joint on the board, the new IC will not be
attached properly.
11.1.3.
Procedure
1. Tack the flat pack IC to the PCB by temporarily soldering
two diagonally opposite pins in the correct positions on
the PCB.
Be certain each pin is located over the correct pad on the PCB.
2. Apply flux to all of the pins on the IC.
3. Being careful to not unsolder the tack points, slide the sol-
dering iron along the tips of the pins while feeding enough
solder to the tip so that it flows under the pins as they are
heated.
11.1.4.
Removing Solder From Between
Pins
1. Add a small amount of solder to the bridged pins.
2. With a hot iron, use a sweeping motion along the flat part
of the pin to draw the solder from between the adjacent
pads.
Содержание KX-NS500AG
Страница 21: ...21 KX NS500AG 5 Location of Controls and Components 5 1 Name and Locations ...
Страница 24: ...24 KX NS500AG 9 1 1 Startup ...
Страница 25: ...25 KX NS500AG ...
Страница 26: ...26 KX NS500AG ...
Страница 27: ...27 KX NS500AG ...
Страница 28: ...28 KX NS500AG 9 1 2 Battery Alarm ...
Страница 29: ...29 KX NS500AG 9 1 3 Using Voice Mail ...
Страница 30: ...30 KX NS500AG Using Voice Mail continued ...
Страница 32: ...32 KX NS500AG 9 2 Power Supply 9 2 1 No Voltage is Output at All 1 Main converter output voltage error C102 ...
Страница 33: ...33 KX NS500AG 9 2 2 No voltage is Output at All 2 Output voltage of Main Converter is Normal C101 C102 ...
Страница 34: ...34 KX NS500AG 9 2 3 41V are Not Output Only 15V is output ...
Страница 35: ...35 KX NS500AG 9 2 4 Battery Backup Function Does Not Operate PSU can Not Charge Batteries ...
Страница 43: ...43 KX NS500AG 11 3 3 Power Supply Board ...
Страница 59: ...59 KX NS500AG 12 2 Memo ...
Страница 73: ...73 KX NS500AG 12 5 Memo ...
Страница 131: ...131 KX NS500AG 16 Appendix ...