3
1 Safety Precautions
1.1.
General Guidelines
1.
IMPORTANT SAFETY NOTICE
There are special components used in this equipment
which are important for safety. These parts are marked by
in the Schematic Diagrams, Circuit Board Layout,
Exploded Views and Replacement Parts List. It is essen-
tial that these critical parts should be replaced with manu-
facturer’s specified parts to prevent X-RADIATION,
shock, fire, or other hazards. Do not modify the original
design without permission of manufacturer.
2. An Isolation Transformer should always be used during
the servicing of AC Adaptor whose chassis is not isolated
from the AC power line. Use a transformer of adequate
power rating as this protects the technician from acci-
dents resulting in personal injury from electrical shocks. It
will also protect AC Adaptor from being damaged by acci-
dental shorting that may occur during servicing.
3. When servicing, observe the original lead dress. If a short
circuit is found, replace all parts which have been over-
heated or damaged by the short circuit.
4. After servicing, see to it that all the protective devices
such as insulation barriers, insulation papers shields are
properly installed.
5. After servicing, make the following leakage current
checks to prevent the customer from being exposed to
shock hazards.
1.2.
Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the
two prongs on the plug.
2. Measure the resistance value, with an ohmmeter,
between the jumpered AC plug and each exposed metal-
lic cabinet part on the equipment such as screwheads,
connectors, control shafts, etc. When the exposed metal-
lic part has a return path to the chassis, the reading
should be between 1 M
Ω
and 5.2 M
Ω
. When the exposed
metal does not have a return path to the chassis, the
reading must be infinity.
1.3.
Leakage Current Hot Check
(See Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use
an isolation transformer for this check.
2. Connect a 1.5 k
Ω
, 10 W resistor, in parallel with a 0.15
μ
F
capacitor, between each exposed metallic part on the set
and a good earth ground, as shown in Figure 1.
3. Use an AC voltmeter, with 1 k
Ω
/V or more sensitivity, to
measure the potential across the resistor.
4. Check each exposed metallic part, and measure the volt-
age at each point.
5. Reverse the AC plug in the AC outlet and repeat each of
the above measurements.
6. The potential at any point should not exceed 0.75 V RMS.
A leakage current tester (Simpson Model 229 or equiva-
lent) may be used to make the hot checks, leakage cur-
rent must not exceed 1/2 mA. In case a measurement is
outside of the limits specified, there is a possibility of a
shock hazard, and the equipment should be repaired and
rechecked before it is returned to the customer.
Figure. 1
Содержание HDC-MDH1GC
Страница 9: ...9 4 Specifications ...
Страница 10: ...10 ...
Страница 13: ...13 ...
Страница 21: ...21 8 3 2 Removal of the Hood ND Case Unit and Focus Ring Fig D2 8 3 3 Removal of the Side Case R Unit Fig D3 ...
Страница 22: ...22 8 3 4 Removal of the Speaker Fig D4 8 3 5 Removal of the Side R OP P C B Unit Fig D5 Fig D6 ...
Страница 23: ...23 8 3 6 Removal of the Side R Int P C B Unit Fig D7 Fig D8 8 3 7 Removal of the Lens Unit Fig D9 ...
Страница 24: ...24 Fig D10 8 3 8 Removal of the Lens Int P C B Unit and Main P C B Unit Fig D11 Fig D12 ...
Страница 25: ...25 8 3 9 Removal of the SD Holder P C B Unit Fig D13 8 3 10 Removal of the Jack P C B Unit Fig D14 ...
Страница 27: ...27 Fig D18 8 3 14 Removal of the Handle Zoom P C B Unit Fig D19 Fig D20 ...
Страница 28: ...28 8 3 15 Removal of the EVF Case Unit Fig D21 Fig D22 8 3 16 Removal of the EVF Angle Adj Case Unit Fig D23 ...
Страница 29: ...29 8 3 17 Removal of the EVF Unit and EVF Int P C B Unit Fig D24 Fig D25 ...
Страница 31: ...31 Fig D30 8 3 21 Removal of the Front P C B Unit Fig D31 Fig D32 8 3 22 Removal of the LCD Case Unit Fig D33 ...
Страница 32: ...32 Fig D34 8 3 23 Removal of the LCD Unit and Moni tor P C B Unit Fig D35 ...
Страница 33: ...33 Fig D36 8 3 24 Removal of the MOS Unit and IR Fil ter Fig D37 ...
Страница 34: ...34 8 3 25 Removal of the Focus Motor Fig D38 8 3 26 Removal of the Zoom Motor Fig D39 ...
Страница 66: ...S 29 ...
Страница 81: ...S 44 ...
Страница 98: ...S 61 S7 6 LCD Section B87 16 98 133 132 101 100 99 81 97 96 B86 B88 84 ...