DA-PU100 Series Administrator's Manual
35
4.1.2.2
Noise in transmission line
Cause:
· Noise from other equipment on the transmission line (inverter, motor, and AC adaptor, etc.)
· Influence of external noise (broadcast wave, radio communication wave, etc.)
Corrective action example:
· Remove noise source from transmission line and keep it away.
· Attach a noise filter to the device that generates noise on the transmission line.
Item
PLC comm. failure device
Remedy
High-speed motors
Electric tool
Hair dryer
Electric Cleaner
Fan
-Things that produce a lot of noise
(sparks) in the high frequency range,
such as cheap dryers, become noise
sources
- Avoid power outlets
near a PLC and use it at
a distance.
- Insert a filter-attached
power strip to use noise
generating equipment.
Lightings
DC-driven halogen light
Touch light
Dimming light
Dimming chandelier
-Impedance changes (phase fluctuation)
-Generates impulsive noise synchronized
with AC
Power strip with Filter Anti-lightning surge power strip
Noise filtered power strip
-Equipment that attenuates the PLC
signal
Insert PLC directly into
wall outlet
Switching regulator
Power charger (e.g. for mobile phones)
-Low impedance
-Impedance fluctuates (phase fluctuation)
Avoid power outlets near
a PLC and use it at a
distance
Содержание HD-PLC DA-PU100
Страница 1: ...Administrator s Manual PLC Adaptor Model No DA PU100 ...
Страница 4: ...DA PU100 Series Administrator s Manual 4 Chapter 1 Introduction ...
Страница 9: ...DA PU100 Series Administrator s Manual 9 Chapter 2 Installation and Operation ...
Страница 25: ...DA PU100 Series Administrator s Manual 25 Chapter 3 PC Tools ...
Страница 32: ...DA PU100 Series Administrator s Manual 32 Chapter 4 Preparation for Operation ...
Страница 58: ...DA PU100 Series Administrator s Manual 58 Chapter 5 Troubleshooting ...
Страница 62: ...DA PU100 Series Administrator s Manual 62 Chapter 6 Specifications ...
Страница 65: ...DA PU100 Series Administrator s Manual 65 7 Dimensions With the fixing brackets attached ...