background image

High Speed High Accuracy Eddy Current Type Digital Displacement Sensor 

GP-X

 

SERIES

1030

FIBER

SENSORS

LASER

SENSORS

PHOTO-

ELECTRIC

SENSORS
MICRO

PHOTO-

ELECTRIC

SENSORS

AREA

SENSORS

LIGHT

CURTAINS

PRESSURE / 

FLOW

SENSORS

INDUCTIVE

PROXIMITY

SENSORS

PARTICULAR

USE 

SENSORS

SENSOR

OPTIONS

SIMPLE

WIRE-SAVING

UNITS

WIRE-SAVING 

SYSTEMS

MEASURE-

MENT

SENSORS

STATIC 

CONTROL

DEVICES

ENDOSCOPE

LASER

MARKERS

PLC /

TERMINALS

HUMAN 

MACHINE 

INTERFACES
ENERGY 

CONSUMPTION 

VISUALIZATION 

COMPONENTS

FA 

COMPONENTS

MACHINE 

VISION 

SYSTEMS

UV 

CURING 

SYSTEMS

Selection 

Guide
Laser  

Displacement

Magnetic 

Displacement

Collimated 

Beam
Digital Panel 

Controller

Metal-sheet 

Double-feed 

Detection

GP-X

GP-A

SPECIFICATIONS

BCD output unit

Controller communication unit

Model No.

GP-XCOM

Item

Current consumption

5 mA or less

Material

Enclosure: ABS

Weight

Net weight: 20 g approx.

Accessory

Mounting bracket [Stainless steel (SUS304)]: 1 pc.

Note:   Each 

GP-XCOM

 is connected using a link cable for controller 

communication units (

SL-F

□, optional). 

When 

GP-XCOM

 is used, controllers cannot communicate if their 

software versions are not compatible (Ver. 1.06 or earlier version with 

Ver 2.00 or later version). 

Check the software version and use the correct combination.

Model No.

GP-XBCD

Item

Current consumption

20 mA or less

Outputs

5 digits BCD, 

Polarity 

indication, VALID

N-channel MOSFET open drain

•  Maximum sink current: 50 mA
•  Applied voltage: 30 V DC or less (between output and GND)
•  Residual voltage: 1 V or less (at 50 mA sink current)

Hold input

Non-voltage contact or NPN open-collector transistor input

•  Low: 0 to 1 V   • High: Open

Material

Enclosure: ABS

Weight

Net weight: 30 g approx.

Accessory

Mounting bracket [Stainless steel (SUS304)]: 1 pc.

Note:  Connects to the control device with 

GP-XBCC3

 cable with connector 

on one end for BCD output unit (3 m 

9.843 ft

 cable length, optional).

Sensor heads

Type

Non-threaded type

Threaded type

For 0.8 mm 

0.031 in

 sensing For 1 mm 

0.039 in

 sensing For 2 mm 

0.079 in

 sensing For 2 mm 

0.079 in

 sensing For 5 mm 

0.197 in

 sensing For 10 mm 

0.394 in

 sensing

Item

Model No.

GP-X3SE

GP-X5SE

GP-X8S

GP-X10M

GP-X12ML

GP-X22KL

Sensing range (Note 2)

0 to 0.8 mm 

0 to

 

0.031 in

0 to 1 mm 

0 to

 

0.039 in

0 to 2 mm 

0 to

 

0.079 in

0 to 2 mm 

0 to

 

0.079 in

0 to 5 mm 

0 to 0.197 in

0 to 10 mm 

0 to

 

0.394 in

Standard sensing object

Stainless steel (SUS304) / Iron sheet [Cold rolled carbon steel (SPCC)] 60 × 60 × t 1 mm 

2.362 × 2.362 × t 0.039 in

Temperature characteristics (Note 3)

0.07 % F.S./°C or less

Environmental resistance

Pollution degree

3 (Industrial environment)

Protection

IP67 (IEC), IP67g (JEM) (Refer to p.1010 for defails of standards.)

Ambient temperature

–10 to +55 °C 

+14 to +131 °F

, Storage: –20 to +70 °C 

–4 to +158 °F

Ambient humidity

35 to 85 % RH, Storage: 35 to 85 % RH

Voltage withstandability

250 V AC for one min. between all supply terminals connected together and enclosure

Insulation resistance

20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure

Vibration resistance

10 to 150 Hz frequency, 0.75 mm 

0.030 in

 amplitude in X, Y and Z directions for two hours each

Shock resistance

500 m/s

2

 acceleration (50 G approx.) in X, Y and Z directions for five times each

Material

Enclosure

Stainless steel (SUS303)

Brass (Nickel plated)

Cable protector

PP

Sensing part

ABS

PAR

ABS

PA

Cable

High frequency coaxial cable with connector, 3 m 

9.843 ft

 long (Note 4)

Cable extension

Extension up to total 10 m 

32.808 ft

 is possible with the optional cable.

Net Weight (Note 5)

40 g approx.

40 g approx.

40 g approx.

50 g approx.

45 g approx.

80 g approx.

Accessories

Nut: 2 pcs., Toothed lock washer: 1 pc.

Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C 

+68 °F

.

 

2) The sensing range is specified for the standard sensing object.

 

3) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and the controller.

 

4) For the flexible cable type, please contact our office. 

 

5) The given weight of the threaded type sensor head is the value including the weight of the nuts and the toothed lock washer.

Содержание GP-X SERIES

Страница 1: ...orresponding to each material stainless steel iron aluminum has already been inputted in the controller enabling the easy selection of the setting that is most suitable for the particular material used Distance Distance Before correction After correction Output value Aluminum Iron Stainless steel Output value Optimal correction of the output feature With a 25 μs ultra high sampling speed the GP X ...

Страница 2: ...9 in Appearance ø8 mm ø0 315 in GP X10M Sensing range 0 to 2 mm 0 to 0 079 in Appearance M10 GP X12ML Sensing range 0 to 5 mm 0 to 0 197 in Appearance M12 IP67g sensor head variation 6 types of sensor heads from the ultra compact ø3 8 mm ø0 150 in cylindrical type to the long range sensing type ø22 mm ø0 866 in are available All sensor heads are oil proof as per IP67g JEM enabling safe stable perf...

Страница 3: ...ontrols such as saving measurement data to PC and the controller s inputted settings and loading stored memory Enables sensors data comparisons and calculations 3 value judgment output for calculating measurement data conformity and calculation results between 2 interconnected controllers is rendered possible The calculation function equipment renders digital panel controllers unnecessary FUNCTION...

Страница 4: ...on Exclusive RC 232C cable is attached BCD output unit GP XBCD Optional 20 kHz high speed data output Mutual interference prevention function The measurement data can be processed quickly in the PLC Sampling rate 20 kHz GP XBCC3 BCD output unit GP XBCD Cable with connector on one end for BCD output unit GP XBCC3 Optional Cable length 3 m 9 843 ft Controller side BCD connector Output side Multi cor...

Страница 5: ...utput Sensor heads Controller Non threaded type sensor head ø3 8 ø0 150 17 0 669 48 1 890 83 3 268 48 1 890 0 to 0 8 mm 0 to 0 031 in GP XC3SE GP X3SE NPN open collector transistor GP XC3SE P GP X3SE PNP open collector transistor ø5 4 ø0 213 17 0 669 0 to 1 mm 0 to 0 039 in GP XC5SE GP X5SE NPN open collector transistor GP XC5SE P GP X5SE PNP open collector transistor ø8 ø0 315 17 0 669 0 to 2 mm ...

Страница 6: ...GP XCOM Up to 8 controllers can be linked Link cable for controller communication unit SL F150 Length 150 mm 5 906 in This cable links the controller communication units Select as per the cable length SL F250 Length 250 mm 9 843 in SL F1000 Length 1 000 mm 39 370 in Intelligent monitor GP XAiM Monitoring settings for each measurement condition and measurement waveforms is enabled by way of a PC On...

Страница 7: ... limit value measured value lower limit value LO ON when lower limit value measured value Short circuit protection Incorporated External input Photo coupler input Input current 9 mA or less Operating voltage ON voltage 17 V or more between 24 V and input OFF voltage 4 V or less between 24 V and input Input impedance 5 kΩ approx Photo coupler input Input current 9 mA or less Operating voltage ON vo...

Страница 8: ...sing For 2 mm 0 079 in sensing For 2 mm 0 079 in sensing For 5 mm 0 197 in sensing For 10 mm 0 394 in sensing Item Model No GP X3SE GP X5SE GP X8S GP X10M GP X12ML GP X22KL Sensing range Note 2 0 to 0 8 mm 0 to 0 031 in 0 to 1 mm 0 to 0 039 in 0 to 2 mm 0 to 0 079 in 0 to 2 mm 0 to 0 079 in 0 to 5 mm 0 to 0 197 in 0 to 10 mm 0 to 0 394 in Standard sensing object Stainless steel SUS304 Iron sheet C...

Страница 9: ...r interference prevention function Used for interference prevention function Users circuit Internal circuit D1 Terminal No 100 mAmax 24 V DC 10 Tr1 100 mA max ZD1 47 Ω 47 Ω Comparative output LO 18 Comparative output GO Output COM 1 ComparativeoutputHI 2 Load Load Load Load Load Strobe output 3 Alarm output Interference prevention output 5 V 4 Analog voltage output 5 to 5 V Note 9 17 For analog ou...

Страница 10: ...0 197 to 0 630 0 44 N m or less GP X8S 0 58 N m or less Mounting with set screw Make sure to use an M3 or smaller set screw having a cup point GP X10M GP X12ML GP X22KL B Attached toothed lock washer Mounting plate B Mounting plate Attached toothed lock washer B Mounting plate Attached toothed lock washer Model No B mm in Tightening torque GP X10M 7 0 276 or more 9 8 N m or less GP X12ML 14 0 551 ...

Страница 11: ...GP X 73 2 874 10 0 394 16 7 0 657 44 5 1 752 48 1 890 Terminal block Connector for RS 232C Sensor head cable length selection switch Coaxial connector for sensor head connection 5 digit dual numerical display Orange Green Comparative output operation indicators Orange Green Orange Timing indicator Green ENTER key SHIFT key Zero set key UP key DOWN key MODE key MODE indicator Orange series Panel cu...

Страница 12: ...f toothed lock washer 35 1 378 20 0 787 3 5 0 138 ø6 4 ø0 252 6 2 0 244 17 0 669 M12 1 0 039 25 7 1 012 GP XCOM Controller communication unit Optional Assembly dimensions with controller Panel thickness dimension 1 to 2 5 0 039 to 0 098 Communication cable Mounting frame Mounting bracket 74 6 2 937 68 2 677 68 2 677 Connector for communication Controller Communication unit Terminator switch GP XBC...