background image

1029

High Speed High Accuracy Eddy Current Type Digital Displacement Sensor 

GP-X

 

SERIES

FIBER

SENSORS

LASER

SENSORS

PHOTO-

ELECTRIC

SENSORS

MICRO

PHOTO-

ELECTRIC

SENSORS

AREA

SENSORS

LIGHT

CURTAINS

PRESSURE / 

FLOW

SENSORS

INDUCTIVE

PROXIMITY

SENSORS

PARTICULAR

USE 

SENSORS

SENSOR

OPTIONS

SIMPLE

WIRE-SAVING

UNITS

WIRE-SAVING 

SYSTEMS

MEASURE-

MENT

SENSORS

STATIC 

CONTROL

DEVICES

ENDOSCOPE

LASER

MARKERS

PLC /

TERMINALS

HUMAN 

MACHINE 

INTERFACES

ENERGY 

CONSUMPTION 

VISUALIZATION 

COMPONENTS

FA 

COMPONENTS

MACHINE 

VISION 

SYSTEMS

UV 

CURING 

SYSTEMS

Selection 

Guide

Laser  

Displacement

Magnetic 

Displacement

Collimated 

Beam

Digital Panel 

Controller

Metal-sheet 

Double-feed 

Detection

GP-X

GP-A

SPECIFICATIONS

Controllers

Type

NPN output

PNP output

Item

Set model No.

GP-XC

GP-XC

-P

Supply voltage

24 V DC ±10 %    Ripple P-P 10 % or less

Current consumption

150 mA or less

Resolution (Note 2)

GP-XC3SE

 / 

GP-XC5SE

: 0.04 % F.S. (64 times average processing)

GP-XC8S

 / 

GP-XC10M

 / 

GP-XC12ML

 / 

GP-XC22KL

: 0.02 % F.S. (64 times average processing)

Sampling frequency

40 kHz (25 μs)

Linearity (Note 2)

Within ±0.3 % F.S.

Temperature characteristics (Note 3)

0.07 % F.S./°C or less

Analog voltage outputs

Output voltage: –5 to +5 V (Note 4), Output impedance: 100 Ω approx.

Response time

75 μs (maximum speed)

Comparative outputs

(HI, GO, LO)

NPN open-collector transistor

•  Maximum sink current: 100 mA

•  Applied voltage:  30 V DC or less 

(between comparative output and 0 V)

•  Residual voltage:  1.6 V or less (at 100 mA sink current) 

0.4 V or less (at 16 mA sink current)

PNP open-collector transistor

•  Maximum source current: 100 mA

•  Applied voltage:  30 V DC or less 

(between comparative output and +V)

•  Residual voltage:  1.6 V or less (at 100 mA source current) 

0.4 V or less (at 16 mA source current)

Utilization category

DC-12 or DC-13

Output number

HI / GO / LO  3 value output

Output operation

HI  : ON when measured value > the upper limit value

GO: ON when upper limit value ≥ measured value ≥ lower limit value

LO : ON when lower limit value > measured value

Short-circuit protection

Incorporated

External input

Photo-coupler input

•  Input current: 9 mA or less

•  Operating voltage: ON voltage 17 V or more (b24 V and input)

 

OFF voltage 4 V or less (b24 V and input)

•  Input impedance: 5 kΩ approx.

Photo-coupler input

•  Input current: 9 mA or less

•  Operating voltage: ON voltage 17 V or more (between 0 V and input)

 

OFF voltage 4 V or less (between 0 V and input)

•  Input impedance: 5 kΩ approx.

Serial I/O

RS-232C

Zero-set setting method

Push button setting / External input setting

Indicators

MODE

Orange LED (lights up when in mode status)

HI

Orange LED (lights up when the upper limit value is exceeded)

GO

Green LED (lights up when within the upper and lower limit value)

LO

Orange LED (lights up when less than the lower limit value)

TIMING

Green LED (lights up as per the external or internal trigger timing)

Upper level digital display part

5 digit orange LED (display of numerical values out of upper and lower limit value)

Lower level digital display part

5 digit green LED (display of numerical values within the upper and lower limit value)

Environmental resistance

Pollution degree

3 (Industrial environment)

Ambient temperature

0 to +50 °C 

+32 to +122 °F

 (No dew condensation), Storage: 0 to +50 °C 

+32 to +122 °F

Ambient humidity

35 to 85 % RH, Storage: 35 to 85 % RH

EMC

EN 61000-6-2, EN 61000-6-4

Vibration resistance

10 to 55 Hz frequency, 0.75 mm 

0.030 in

 amplitude in X, Y and Z directions for two hours each

Shock resistance

100 m/s

2

 acceleration (10 G approx.) in X, Y and Z directions for five times each

Material

Enclosure: Polycarbonate

Weight

Net weight: 120 g approx.

Accessory

ATA4811

 (Controller mounting frame): 1 set

Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C 

+68 °F

.

 

2)  This value was obtained at a co25 °C 

+77 °F

.

 

3) This value represents 20 to 60 % of the maximum sensing distance when combining the sensor head and controller.

 

4) Adjusted to a 0 to +5 V factory setting.

Содержание GP-X SERIES

Страница 1: ...orresponding to each material stainless steel iron aluminum has already been inputted in the controller enabling the easy selection of the setting that is most suitable for the particular material used Distance Distance Before correction After correction Output value Aluminum Iron Stainless steel Output value Optimal correction of the output feature With a 25 μs ultra high sampling speed the GP X ...

Страница 2: ...9 in Appearance ø8 mm ø0 315 in GP X10M Sensing range 0 to 2 mm 0 to 0 079 in Appearance M10 GP X12ML Sensing range 0 to 5 mm 0 to 0 197 in Appearance M12 IP67g sensor head variation 6 types of sensor heads from the ultra compact ø3 8 mm ø0 150 in cylindrical type to the long range sensing type ø22 mm ø0 866 in are available All sensor heads are oil proof as per IP67g JEM enabling safe stable perf...

Страница 3: ...ontrols such as saving measurement data to PC and the controller s inputted settings and loading stored memory Enables sensors data comparisons and calculations 3 value judgment output for calculating measurement data conformity and calculation results between 2 interconnected controllers is rendered possible The calculation function equipment renders digital panel controllers unnecessary FUNCTION...

Страница 4: ...on Exclusive RC 232C cable is attached BCD output unit GP XBCD Optional 20 kHz high speed data output Mutual interference prevention function The measurement data can be processed quickly in the PLC Sampling rate 20 kHz GP XBCC3 BCD output unit GP XBCD Cable with connector on one end for BCD output unit GP XBCC3 Optional Cable length 3 m 9 843 ft Controller side BCD connector Output side Multi cor...

Страница 5: ...utput Sensor heads Controller Non threaded type sensor head ø3 8 ø0 150 17 0 669 48 1 890 83 3 268 48 1 890 0 to 0 8 mm 0 to 0 031 in GP XC3SE GP X3SE NPN open collector transistor GP XC3SE P GP X3SE PNP open collector transistor ø5 4 ø0 213 17 0 669 0 to 1 mm 0 to 0 039 in GP XC5SE GP X5SE NPN open collector transistor GP XC5SE P GP X5SE PNP open collector transistor ø8 ø0 315 17 0 669 0 to 2 mm ...

Страница 6: ...GP XCOM Up to 8 controllers can be linked Link cable for controller communication unit SL F150 Length 150 mm 5 906 in This cable links the controller communication units Select as per the cable length SL F250 Length 250 mm 9 843 in SL F1000 Length 1 000 mm 39 370 in Intelligent monitor GP XAiM Monitoring settings for each measurement condition and measurement waveforms is enabled by way of a PC On...

Страница 7: ... limit value measured value lower limit value LO ON when lower limit value measured value Short circuit protection Incorporated External input Photo coupler input Input current 9 mA or less Operating voltage ON voltage 17 V or more between 24 V and input OFF voltage 4 V or less between 24 V and input Input impedance 5 kΩ approx Photo coupler input Input current 9 mA or less Operating voltage ON vo...

Страница 8: ...sing For 2 mm 0 079 in sensing For 2 mm 0 079 in sensing For 5 mm 0 197 in sensing For 10 mm 0 394 in sensing Item Model No GP X3SE GP X5SE GP X8S GP X10M GP X12ML GP X22KL Sensing range Note 2 0 to 0 8 mm 0 to 0 031 in 0 to 1 mm 0 to 0 039 in 0 to 2 mm 0 to 0 079 in 0 to 2 mm 0 to 0 079 in 0 to 5 mm 0 to 0 197 in 0 to 10 mm 0 to 0 394 in Standard sensing object Stainless steel SUS304 Iron sheet C...

Страница 9: ...r interference prevention function Used for interference prevention function Users circuit Internal circuit D1 Terminal No 100 mAmax 24 V DC 10 Tr1 100 mA max ZD1 47 Ω 47 Ω Comparative output LO 18 Comparative output GO Output COM 1 ComparativeoutputHI 2 Load Load Load Load Load Strobe output 3 Alarm output Interference prevention output 5 V 4 Analog voltage output 5 to 5 V Note 9 17 For analog ou...

Страница 10: ...0 197 to 0 630 0 44 N m or less GP X8S 0 58 N m or less Mounting with set screw Make sure to use an M3 or smaller set screw having a cup point GP X10M GP X12ML GP X22KL B Attached toothed lock washer Mounting plate B Mounting plate Attached toothed lock washer B Mounting plate Attached toothed lock washer Model No B mm in Tightening torque GP X10M 7 0 276 or more 9 8 N m or less GP X12ML 14 0 551 ...

Страница 11: ...GP X 73 2 874 10 0 394 16 7 0 657 44 5 1 752 48 1 890 Terminal block Connector for RS 232C Sensor head cable length selection switch Coaxial connector for sensor head connection 5 digit dual numerical display Orange Green Comparative output operation indicators Orange Green Orange Timing indicator Green ENTER key SHIFT key Zero set key UP key DOWN key MODE key MODE indicator Orange series Panel cu...

Страница 12: ...f toothed lock washer 35 1 378 20 0 787 3 5 0 138 ø6 4 ø0 252 6 2 0 244 17 0 669 M12 1 0 039 25 7 1 012 GP XCOM Controller communication unit Optional Assembly dimensions with controller Panel thickness dimension 1 to 2 5 0 039 to 0 098 Communication cable Mounting frame Mounting bracket 74 6 2 937 68 2 677 68 2 677 Connector for communication Controller Communication unit Terminator switch GP XBC...

Отзывы: