1033
High Speed High Accuracy Eddy Current Type Digital Displacement Sensor
GP-X
SERIES
FIBER
SENSORS
LASER
SENSORS
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Laser
Displacement
Magnetic
Displacement
Collimated
Beam
Digital Panel
Controller
Metal-sheet
Double-feed
Detection
GP-X
GP-A
Sensor head
GP-X8S
Sensor head
GP-X10M
ø2.5
ø0.098
high frequency
coaxial cable, 3 m
9.843 ft
long
(6.2)
(0.244)
17
0.669
ø8
ø0.315
(25.7)
(1.012)
(17)
(0.669)
(ø6.4)
(ø0.252)
Coaxial connector for
controller connection
M10 × 1
0.039
Nut
Toothed lock washer (internal tooth)
3
0.118
ø18
ø0.709
(6.2)
(0.244)
(25.7)
(1.012)
(17)
(0.669)
(ø6.4)
(ø0.252)
ø2.5
ø0.098
high frequency
coaxial cable, 3 m
9.843 ft
long
Coaxial connecfor for
controller connection
14
0.551
17
0.669
Controller
GP-X
73
2.874
10
0.394
(16.7)
(0.657)
□44.5
□1.752
□48
□1.890
Terminal block
Connector for RS-232C
Sensor head cable length selection switch
Coaxial connector for sensor head connection
5-digit, dual numerical display
(Orange / Green)
Comparative output operation indicators
(Orange / Green / Orange)
Timing indicator (Green)
ENTER key
SHIFT key
Zero-set key
UP key
DOWN key
MODE key
MODE indicator
(Orange)
series
Panel cut-out dimensions
<When BCD output unit / controller communication unit not mounted>
<When BCD output unit / controller communication unit mounted>
Minimum 90
3.543
When mounted in series
A = (48 × n – 2.5)
A
+0.6
0
+0.6
0
A = (1.890 × n – 0.098)
+0.024
0
45
+0.024
0
1.772
+0.6
0
45
+0.024
0
1.772
Minimum 90
3.543
Minimum 100
3.937
+0.6
0
45
+0.024
0
1.772
+0.6
0
45
+0.024
0
1.772
Note: The panel thickness should be 1 to 5 mm
0.039 to 0.197 in
.
Note: The panel thickness should be 1 to 2.5 mm
0.039 to 0.098 in
.
DIMENSIONS (Unit: mm
in
)
The CAD data in the dimensions can be downloaded from our website.
ø2.5
ø0.098
high frequency
coaxial cable, 3 m
9.843 ft
long
Coaxial connector for
controller connection
(25.7)
(1.012)
(17)
(0.669)
(ø6.4)
(ø0.252)
17
0.669
ø3.8
ø0.150
Sensor head
GP-X3SE
ø2.5
ø0.098
high frequency
coaxial cable, 3 m
9.843 ft
long
Coaxial connector for
controller connection
(6.2)
(0.244)
17
0.669
ø5.4
ø0.213
(25.7)
(1.012)
(17)
(0.669)
(ø6.4)
(ø0.252)
Sensor head
GP-X5SE