High Speed High Accuracy Eddy Current Type Digital Displacement Sensor 

GP-X

 

SERIES

1026

Selection 

Guide

Laser  

Displacement

Magnetic 

Displacement

Collimated 

Beam

Digital Panel 

Controller

Metal-sheet 

Double-feed Detection

GP-X

GP-A

FIBER

SENSORS

LASER

SENSORS

PHOTOELECTRIC

SENSORS
MICRO

PHOTOELECTRIC

SENSORS
AREA

SENSORS

LIGHT

CURTAINS
PRESSURE / 

FLOW

SENSORS

INDUCTIVE

PROXIMITY

SENSORS
PARTICULAR

USE SENSORS

SENSOR

OPTIONS
SIMPLE

WIRE-SAVING

UNITS
WIRE-SAVING 

SYSTEMS

MEASUREMENT

SENSORS

STATIC CONTROL

DEVICES

ENDOSCOPE

LASER

MARKERS

PLC /

TERMINALS

HUMAN MACHINE 

INTERFACES
ENERGY CONSUMPTION 

VISUALIZATION 

COMPONENTS

FA COMPONENTS

MACHINE VISION 

SYSTEMS

UV CURING 

SYSTEMS

Datalink between sensors possible

The controller communication unit 

GP-XCOM

 (optional) can be linked to up to 8 controllers and load via just one  

 

RS-232C cable each controller settings and measurement data to a PC.

Link cable

Controller communication unit

Data sent to a PC

via the RS-232C

Maximum of eight units

OPTIONS

An intelligent monitor (GP-XAiM) optimal for collecting and analyzing measurement data 

is also available

An intelligent monitor capable of the settings for each measurement 

conditions and waveform display monitoring. It can perform waveform 

monitoring, which could until now only be done by the oscilloscope, as 

well as the simple loading and saving onto a PC of settings for each 

condition and function. (Exclusive RC-232C cable is attached.)

BCD output unit GP-XBCD (Optional)

20 kHz high-speed data output

Mutual interference prevention function

The measurement data can be processed quickly in the 

PLC. (Sampling rate: 20 kHz)

GP-XBCC3 

BCD output unit 

GP-XBCD 

Cable with connector on one end for
BCD output unit

GP-XBCC3

 (Optional)

Cable length: 3 m 

9.843 ft

Controller side: BCD connector

Output side: Multi-core cable

The sensor head can be made interference prevention 

by linking up to 8 controllers via an interference 

prevention output cable and shifting the oscillation 

timing. This enables precise measurements to be 

obtained even in cases where many sensor heads are 

crowded in the same area.

Removable type terminal block

It is equipped with a removable 

type European terminal block 

very convenient during assembly, 

when dividing the equipment into 

segments or when performing 

maintenance. It also features 

an reverse insertion prevention 

construction.

European terminal block

4 types of selectable memory functions

The setting data can be processed in 4 types of memory 

when measuring. This function enables either the changing 

of the workpiece, the sensing of multiple products or 

sensing after product changeover to be done smoothly.

4 types of measurement modes available

Measurement modes compatible to the most widely used 

applications are available. Because of this, inputting 

setting values can be done with ease. Please select the 

most appropriate mode to suit your specific application.

<Height sensing mode>

<Rotation / eccentricity / vibration sensing mode>

<Stroke end sensing mode>

GP-X12ML

GP-X3S

<Maunally set mode>

GP-X10M

Содержание GP-X SERIES

Страница 1: ...orresponding to each material stainless steel iron aluminum has already been inputted in the controller enabling the easy selection of the setting that is most suitable for the particular material used Distance Distance Before correction After correction Output value Aluminum Iron Stainless steel Output value Optimal correction of the output feature With a 25 μs ultra high sampling speed the GP X ...

Страница 2: ...9 in Appearance ø8 mm ø0 315 in GP X10M Sensing range 0 to 2 mm 0 to 0 079 in Appearance M10 GP X12ML Sensing range 0 to 5 mm 0 to 0 197 in Appearance M12 IP67g sensor head variation 6 types of sensor heads from the ultra compact ø3 8 mm ø0 150 in cylindrical type to the long range sensing type ø22 mm ø0 866 in are available All sensor heads are oil proof as per IP67g JEM enabling safe stable perf...

Страница 3: ...ontrols such as saving measurement data to PC and the controller s inputted settings and loading stored memory Enables sensors data comparisons and calculations 3 value judgment output for calculating measurement data conformity and calculation results between 2 interconnected controllers is rendered possible The calculation function equipment renders digital panel controllers unnecessary FUNCTION...

Страница 4: ...on Exclusive RC 232C cable is attached BCD output unit GP XBCD Optional 20 kHz high speed data output Mutual interference prevention function The measurement data can be processed quickly in the PLC Sampling rate 20 kHz GP XBCC3 BCD output unit GP XBCD Cable with connector on one end for BCD output unit GP XBCC3 Optional Cable length 3 m 9 843 ft Controller side BCD connector Output side Multi cor...

Страница 5: ...utput Sensor heads Controller Non threaded type sensor head ø3 8 ø0 150 17 0 669 48 1 890 83 3 268 48 1 890 0 to 0 8 mm 0 to 0 031 in GP XC3SE GP X3SE NPN open collector transistor GP XC3SE P GP X3SE PNP open collector transistor ø5 4 ø0 213 17 0 669 0 to 1 mm 0 to 0 039 in GP XC5SE GP X5SE NPN open collector transistor GP XC5SE P GP X5SE PNP open collector transistor ø8 ø0 315 17 0 669 0 to 2 mm ...

Страница 6: ...GP XCOM Up to 8 controllers can be linked Link cable for controller communication unit SL F150 Length 150 mm 5 906 in This cable links the controller communication units Select as per the cable length SL F250 Length 250 mm 9 843 in SL F1000 Length 1 000 mm 39 370 in Intelligent monitor GP XAiM Monitoring settings for each measurement condition and measurement waveforms is enabled by way of a PC On...

Страница 7: ... limit value measured value lower limit value LO ON when lower limit value measured value Short circuit protection Incorporated External input Photo coupler input Input current 9 mA or less Operating voltage ON voltage 17 V or more between 24 V and input OFF voltage 4 V or less between 24 V and input Input impedance 5 kΩ approx Photo coupler input Input current 9 mA or less Operating voltage ON vo...

Страница 8: ...sing For 2 mm 0 079 in sensing For 2 mm 0 079 in sensing For 5 mm 0 197 in sensing For 10 mm 0 394 in sensing Item Model No GP X3SE GP X5SE GP X8S GP X10M GP X12ML GP X22KL Sensing range Note 2 0 to 0 8 mm 0 to 0 031 in 0 to 1 mm 0 to 0 039 in 0 to 2 mm 0 to 0 079 in 0 to 2 mm 0 to 0 079 in 0 to 5 mm 0 to 0 197 in 0 to 10 mm 0 to 0 394 in Standard sensing object Stainless steel SUS304 Iron sheet C...

Страница 9: ...r interference prevention function Used for interference prevention function Users circuit Internal circuit D1 Terminal No 100 mAmax 24 V DC 10 Tr1 100 mA max ZD1 47 Ω 47 Ω Comparative output LO 18 Comparative output GO Output COM 1 ComparativeoutputHI 2 Load Load Load Load Load Strobe output 3 Alarm output Interference prevention output 5 V 4 Analog voltage output 5 to 5 V Note 9 17 For analog ou...

Страница 10: ...0 197 to 0 630 0 44 N m or less GP X8S 0 58 N m or less Mounting with set screw Make sure to use an M3 or smaller set screw having a cup point GP X10M GP X12ML GP X22KL B Attached toothed lock washer Mounting plate B Mounting plate Attached toothed lock washer B Mounting plate Attached toothed lock washer Model No B mm in Tightening torque GP X10M 7 0 276 or more 9 8 N m or less GP X12ML 14 0 551 ...

Страница 11: ...GP X 73 2 874 10 0 394 16 7 0 657 44 5 1 752 48 1 890 Terminal block Connector for RS 232C Sensor head cable length selection switch Coaxial connector for sensor head connection 5 digit dual numerical display Orange Green Comparative output operation indicators Orange Green Orange Timing indicator Green ENTER key SHIFT key Zero set key UP key DOWN key MODE key MODE indicator Orange series Panel cu...

Страница 12: ...f toothed lock washer 35 1 378 20 0 787 3 5 0 138 ø6 4 ø0 252 6 2 0 244 17 0 669 M12 1 0 039 25 7 1 012 GP XCOM Controller communication unit Optional Assembly dimensions with controller Panel thickness dimension 1 to 2 5 0 039 to 0 098 Communication cable Mounting frame Mounting bracket 74 6 2 937 68 2 677 68 2 677 Connector for communication Controller Communication unit Terminator switch GP XBC...

Отзывы: