INDICATION (PLUG ‘N PLAY FUNCTION DEVICES) CONTINUED 

PLUG ‘N PLAY Modular Component Accessories 
Sold Separately, Not Included With Base Model Fan

PLUG ‘N PLAY Modular Component Accessories      
Sold Separately, Not Included With Base Model Fan

FV-CSVK1 + FV-MSVK1

FV-CSVK1 + FV-VS15VK1

Turns the fan on for 20 minutes when either 
motion or excess humidity is detected.

Cycles the fan to high speed from low speed 
for the amount of time selected on the Control 
Dial based upon detection of excess humidity.

PLUG ‘N PLAY Modular 
Components used in 
Combinations

FV-MSVK1 + FV-VS15VK1

Cycles the fan to high speed from low speed 
for the amount of time selected on the Control 
Dial based upon motion within the room.

Fan 

operation

Time delay 

operation

OUTSIDE

Human 
active

Motion

Module FV-MSVK1,  FV-CSVK1 (Not  included)

INSIDE

FV-CSVK1 only

Fan 
ON/OFF

20 minutes 
time delay

FV-MSVK1 only

Fan 
active

At low 
speed

When motion or 
excess humidity is 
detected, fan runs 
at high speed.

Remains running 
at high speed until 
the delay time has 
passed.

FV-CSVK1 + FV-VS15VK1 Fan 

Hi/Low speed

Depend on 
FV-VS15VK1 Time 

delay setting

FV-MSVK1 + FV-VS15VK1

FV-MSVK1 Motion Sensor module turns the base fan on or boosts 

to higher speed when motion is detected when using in combination 

with the FV-VS15VK1. The Motion Sensor is pre-set to run for 20 

minutes; it will then re-check for movement; if detected the fan will 

run for another 20 minutes cycle. The Motion Sensor detects within 

the range shown below.

The distance that motion 

can be detected is limited

to 10 feet (3m). The field 

of view of the sensor is 90

°

.

(Room temperature is 25 C).

Factory setting : 20 minutes.
Position ”    ” : For factory use

Factory setting is around 50%.
Timer preset selector positions

Timer

[min]

0.5

1

2

3

5

10

20

30

60

1. The product will run when environment humidity rise rapidly but not reach to the humidity 

    setting, and stop after delay preset time.

2. Humidity setting selector is stepless change between 30 %RH ~ 80 %RH.

3. The humidity detected by sensor may differ from the value on your hygrometer.

4. The product may turn on and off cause by the unstable environment humidity, you can improve

    it by adjusting the Humidity setting selector.

English

Humidity selector range from aroun 30% to 80%.

1115 MODEL

0511 MODEL

1115 MODEL

0511 MODEL

Содержание FV-0511VKL2

Страница 1: ...L2 Representative models 2 3 3 4 4 5 5 5 5 6 6 7 7 8 8 10 10 11 READ AND SAVE THESE INSTRUCTIONS Thank you for purchasing this Panasonic product Please read these instructions carefully before attempting to install operate or service the Panasonic product Please carefully read the GENERAL SAFETY INFORMATION Failure to comply with instructions could result in personal injury or property damage Plea...

Страница 2: ...contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by qualified person s in acc...

Страница 3: ...eed control device Solid state controls may cause harmonic distortion which can cause motor humming noise Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupation Safety and Health Act OSHA Always disconnect the power source before working on or near the fan motor or junction box Protect the supply wiring from sharp edges oil grease hot surfaces c...

Страница 4: ...ty sirocco fan developed to reduce the noise level The FCC Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not insta...

Страница 5: ...5VKL2 10 1 4 260 5 7 8 151 5 7 8 148 13 330 7 1 2 190 1 1 4 30 4 1 2 114 1 1 2 37 3 7 8 100 12 304 3 3 8 86 13 1 4 15 1 2 336 394 16 1 2 18 3 4 419 480 21 1 4 23 1 2 540 597 3 3 8 86 6 5 8 169 10 1 4 261 13 330 3 7 8 100 3 7 8 100 1 8 3 4 5 2 FV 0511VKL2 FV 1115VKL2 Part name Blade Grille Part name No No 8 2 4 1 3 5 6 10 12 11 Motion sensor location FV MSVK1 not included Multi Speed module FV 0511...

Страница 6: ... the selected amount of time before returning to the lower speed setting chosen on the CFM dial Pick A Flow CFM Multi Speed Air volume CFM 50 110 110 130 150 0 0 0 0 0 0 40 40 40 60 60 60 40 60 60 80 80 80 40 70 80 100 100 100 40 70 80 100 100 110 120 30 30 30 50 50 50 40 50 50 70 70 70 40 70 70 90 90 90 40 70 90 100 110 110 Factory setting 20 minutes Delay Time position 0 Manual wall switch contr...

Страница 7: ...FV VS15VK1 Fan Hi Low speed Depend on FV VS15VK1 Time delay setting FV MSVK1 FV VS15VK1 FV MSVK1 Motion Sensor module turns the base fan on or boosts to higher speed when motion is detected when using in combination with the FV VS15VK1 The Motion Sensor is pre set to run for 20 minutes it will then re check for movement if detected the fan will run for another 20 minutes cycle The Motion Sensor de...

Страница 8: ...ast bracket to joists by drilling 2 tapping screws which have been fixed on it Fig 2 TM TM 3 Adjust the length of Flex Z Fast bracket as the spacing between joists and install to joists by drilling the other 2 tapping screws which have been fixed on it Fig 3 4 Remove junction box cover and secure conduit or stress relief to junction box knock out hole Fig 4 TM 6 Install the adaptor to Flex Z Fast ...

Страница 9: ...Secure machine screw M4X8 to the suitable hole and not touch the Flex Z Fast bracket Please fix the screw carefully to avoid screw slip teeth TM 9 Finish ceiling work Ceiling hole should be aligned with the inside edge of the flange Fig 7 CAUTION CAUTION 10 Insert the grille mounting spring on the wiring side into the slot and insert the plug connector into the housing of the lighting unit Fig 8 B...

Страница 10: ...g 11 2 Follow the step 1 4 5 7 on INSTALLATION NEW CONSTRUCTION Before connect the circular duct to the adaptor should pull down the circular duct from the ceiling Disconnect power source before working on unit 5 Follow the step 10 to 12 on INSTALLATION NEW CONSTRUCTION TM TM 3 Install the adaptor to Flex Z Fast bracket by using 2 self drilling screws Fig 12 4 Secure the fan body to Flex Z Fast br...

Страница 11: ...t into hot water Use non abrasive kitchen detergent wipe dry with clean cloth Fig 16 3 The grille should be dry after cleaning 4 Remove dust and dirt from fan body using a vacuum cleaner Fig 17 5 Using a cloth dampened with kitchen detergent remove any dirt from fan body Wipe dry with clean cloth Fig 18 6 Reinstall grille 1 Remove grille by pulling down one mounting spring Fig 14 then pull down th...

Страница 12: ...ment and absorbs sound Clamps plus mastic or approved foil faced tape at all flex joints Foil tape tightly covers all metal duct joints glue PVC joints Properly insulate the area around the fan to minimize building heat loss and gain Fig 19 Loose fill or batt insulation can be placed directly over the fan housing in the attic Our fans does not create excessive heat that is a common problem with re...

Отзывы: