SPECIFICATIONS

PRODUCT

 

SERVICE

Specifications for Base Model fans

Reference performance based on HVI Procedures 915, 916, and 920. [( ) Standby wattage.]

Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only. 
Your product is designed and manufactured to ensure a minimum of maintenance. Should your unit 
require service or parts, call Panasonic Call Center at 1-866-292-7299 (USA) or 1-800-669-5165 (Canada).

HVI Certified performance based on HVI Procedures 915, 916, and 920.

Specifications for Multi Speed fans

Model No.

Air

direction

Exhaust

4 or 6

Exhaust

Voltage

(V)

Frequency

(Hz)

Noise

(sones)

Speed

(rpm)

Power   (W)

Fan

Lighting

unit

Weight

lb

.

Duct

diameter

(inches)

Air volume

at 0.1"WG

(CFM)

FV-0511VKSL2
FV-0511VKL2

FV-1115VKL2

10

110

<0.3

<0.3

<0.3

<0.3

0.4

0.5

7.5

3.2

10.4

5.3

14.9

 10.5

648

682

722

730

811

958

110

130

150

50

80

10.6(4.8)

10.7(4.9)

10

6

Fig.19

lnsulation

4 inches or 6 inches roof jack, wall cap,

or soffit vent with backdraft damper
Mechanically connect duct to termination

and seal with mastic or approved foil

faced tape

2-3 ft straight run before elbow

Short piece of flexible duct helps

alignment and absorbs sound.

Clamps plus mastic or approved

foil faced tape at all flex joints

Foil tape tightly covers all metal

duct joints (glue PVC joints)

Properly insulate the area around the fan to

minimize building heat loss and gain. (Fig.19)

Loose fill or batt insulation can be placed

directly over the fan housing in the attic.

Our fans does not create excessive heat that

is a common problem with recessed light

fixtures or some competitor’s fan/light

combination. Our efficient, cool-running

motors do not create enough ambient heat

to be subjected to these limitations.

The ducting from this fan to the outside of

the building has a strong effect on the air flow, 

noise and energy use of the fan. Use the shortest,

straightest duct routing possible for best performance, and avoid installing the fan with smaller

ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold

growth. Fans installed with existing ducts may not achieve their rated air flow.

ln attic installation,

caulk box to drywall

PRACTICAL GUIDE TO INSTALLATION

Model No.

Air

direction

Exhaust

Exhaust

Voltage

(V)

Frequency

(Hz)

Noise

(sones)

Speed

(rpm)

Power   (W)

Fan

Lighting

unit

Weight

lb

.

Duct

diameter

(inches)

Air volume

at 0.1"WG

(CFM)

FV-0511VKSL2,

FV-0511VKL2
(Plug-in 
FV-VS15VK1)

10

<0.3

<0.3

8.2

4.6

6.7

3.7

5.3

3.2
2.7
2.5

908

868

811

785

750

710

730

720

80

60

40

0

90

70

50

30

100

10.6(4.8)

FV-1115VKL2
(Plug-in 
FV-VS15VK1)

10

8.4

5.0

7.5

4.6

6.0

3.8
3.3
3.1

670

648

636

627

625

610

613

621

100

80

60

0

110

90

70

50

120

10.7(4.9)

6

<0.3

<0.3

<0.3

<0.3

<0.3

<0.3

<0.3

<0.3

<0.3

<0.3

<0.3

<0.3

<0.3
<0.3

Содержание FV-0511VKL2

Страница 1: ...L2 Representative models 2 3 3 4 4 5 5 5 5 6 6 7 7 8 8 10 10 11 READ AND SAVE THESE INSTRUCTIONS Thank you for purchasing this Panasonic product Please read these instructions carefully before attempting to install operate or service the Panasonic product Please carefully read the GENERAL SAFETY INFORMATION Failure to comply with instructions could result in personal injury or property damage Plea...

Страница 2: ...contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by qualified person s in acc...

Страница 3: ...eed control device Solid state controls may cause harmonic distortion which can cause motor humming noise Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupation Safety and Health Act OSHA Always disconnect the power source before working on or near the fan motor or junction box Protect the supply wiring from sharp edges oil grease hot surfaces c...

Страница 4: ...ty sirocco fan developed to reduce the noise level The FCC Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not insta...

Страница 5: ...5VKL2 10 1 4 260 5 7 8 151 5 7 8 148 13 330 7 1 2 190 1 1 4 30 4 1 2 114 1 1 2 37 3 7 8 100 12 304 3 3 8 86 13 1 4 15 1 2 336 394 16 1 2 18 3 4 419 480 21 1 4 23 1 2 540 597 3 3 8 86 6 5 8 169 10 1 4 261 13 330 3 7 8 100 3 7 8 100 1 8 3 4 5 2 FV 0511VKL2 FV 1115VKL2 Part name Blade Grille Part name No No 8 2 4 1 3 5 6 10 12 11 Motion sensor location FV MSVK1 not included Multi Speed module FV 0511...

Страница 6: ... the selected amount of time before returning to the lower speed setting chosen on the CFM dial Pick A Flow CFM Multi Speed Air volume CFM 50 110 110 130 150 0 0 0 0 0 0 40 40 40 60 60 60 40 60 60 80 80 80 40 70 80 100 100 100 40 70 80 100 100 110 120 30 30 30 50 50 50 40 50 50 70 70 70 40 70 70 90 90 90 40 70 90 100 110 110 Factory setting 20 minutes Delay Time position 0 Manual wall switch contr...

Страница 7: ...FV VS15VK1 Fan Hi Low speed Depend on FV VS15VK1 Time delay setting FV MSVK1 FV VS15VK1 FV MSVK1 Motion Sensor module turns the base fan on or boosts to higher speed when motion is detected when using in combination with the FV VS15VK1 The Motion Sensor is pre set to run for 20 minutes it will then re check for movement if detected the fan will run for another 20 minutes cycle The Motion Sensor de...

Страница 8: ...ast bracket to joists by drilling 2 tapping screws which have been fixed on it Fig 2 TM TM 3 Adjust the length of Flex Z Fast bracket as the spacing between joists and install to joists by drilling the other 2 tapping screws which have been fixed on it Fig 3 4 Remove junction box cover and secure conduit or stress relief to junction box knock out hole Fig 4 TM 6 Install the adaptor to Flex Z Fast ...

Страница 9: ...Secure machine screw M4X8 to the suitable hole and not touch the Flex Z Fast bracket Please fix the screw carefully to avoid screw slip teeth TM 9 Finish ceiling work Ceiling hole should be aligned with the inside edge of the flange Fig 7 CAUTION CAUTION 10 Insert the grille mounting spring on the wiring side into the slot and insert the plug connector into the housing of the lighting unit Fig 8 B...

Страница 10: ...g 11 2 Follow the step 1 4 5 7 on INSTALLATION NEW CONSTRUCTION Before connect the circular duct to the adaptor should pull down the circular duct from the ceiling Disconnect power source before working on unit 5 Follow the step 10 to 12 on INSTALLATION NEW CONSTRUCTION TM TM 3 Install the adaptor to Flex Z Fast bracket by using 2 self drilling screws Fig 12 4 Secure the fan body to Flex Z Fast br...

Страница 11: ...t into hot water Use non abrasive kitchen detergent wipe dry with clean cloth Fig 16 3 The grille should be dry after cleaning 4 Remove dust and dirt from fan body using a vacuum cleaner Fig 17 5 Using a cloth dampened with kitchen detergent remove any dirt from fan body Wipe dry with clean cloth Fig 18 6 Reinstall grille 1 Remove grille by pulling down one mounting spring Fig 14 then pull down th...

Страница 12: ...ment and absorbs sound Clamps plus mastic or approved foil faced tape at all flex joints Foil tape tightly covers all metal duct joints glue PVC joints Properly insulate the area around the fan to minimize building heat loss and gain Fig 19 Loose fill or batt insulation can be placed directly over the fan housing in the attic Our fans does not create excessive heat that is a common problem with re...

Отзывы: