SPECIFICATIONS
PRODUCT
SERVICE
Specifications for Base Model fans
Reference performance based on HVI Procedures 915, 916, and 920. [( ) Standby wattage.]
Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only.
Your product is designed and manufactured to ensure a minimum of maintenance. Should your unit
require service or parts, call Panasonic Call Center at 1-866-292-7299 (USA) or 1-800-669-5165 (Canada).
HVI Certified performance based on HVI Procedures 915, 916, and 920.
Specifications for Multi Speed fans
Model No.
Air
direction
Exhaust
4 or 6
Exhaust
Voltage
(V)
Frequency
(Hz)
Noise
(sones)
Speed
(rpm)
Power (W)
Fan
Lighting
unit
Weight
lb
.
Duct
diameter
(inches)
Air volume
at 0.1"WG
(CFM)
FV-0511VKSL2
FV-0511VKL2
FV-1115VKL2
10
110
<0.3
<0.3
<0.3
<0.3
0.4
0.5
7.5
3.2
10.4
5.3
14.9
10.5
648
682
722
730
811
958
110
130
150
50
80
10.6(4.8)
10.7(4.9)
10
6
Fig.19
lnsulation
4 inches or 6 inches roof jack, wall cap,
or soffit vent with backdraft damper
Mechanically connect duct to termination
and seal with mastic or approved foil
faced tape
2-3 ft straight run before elbow
Short piece of flexible duct helps
alignment and absorbs sound.
Clamps plus mastic or approved
foil faced tape at all flex joints
Foil tape tightly covers all metal
duct joints (glue PVC joints)
Properly insulate the area around the fan to
minimize building heat loss and gain. (Fig.19)
Loose fill or batt insulation can be placed
directly over the fan housing in the attic.
Our fans does not create excessive heat that
is a common problem with recessed light
fixtures or some competitor’s fan/light
combination. Our efficient, cool-running
motors do not create enough ambient heat
to be subjected to these limitations.
The ducting from this fan to the outside of
the building has a strong effect on the air flow,
noise and energy use of the fan. Use the shortest,
straightest duct routing possible for best performance, and avoid installing the fan with smaller
ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold
growth. Fans installed with existing ducts may not achieve their rated air flow.
ln attic installation,
caulk box to drywall
PRACTICAL GUIDE TO INSTALLATION
Model No.
Air
direction
Exhaust
Exhaust
Voltage
(V)
Frequency
(Hz)
Noise
(sones)
Speed
(rpm)
Power (W)
Fan
Lighting
unit
Weight
lb
.
Duct
diameter
(inches)
Air volume
at 0.1"WG
(CFM)
FV-0511VKSL2,
FV-0511VKL2
(Plug-in
FV-VS15VK1)
10
<0.3
<0.3
8.2
4.6
6.7
3.7
5.3
3.2
2.7
2.5
908
868
811
785
750
710
730
720
80
60
40
0
90
70
50
30
100
10.6(4.8)
FV-1115VKL2
(Plug-in
FV-VS15VK1)
10
8.4
5.0
7.5
4.6
6.0
3.8
3.3
3.1
670
648
636
627
625
610
613
621
100
80
60
0
110
90
70
50
120
10.7(4.9)
6
<0.3
<0.3
<0.3
<0.3
<0.3
<0.3
<0.3
<0.3
<0.3
<0.3
<0.3
<0.3
<0.3
<0.3