PLEASE  READ  PRIOR  T O  I N ST A LLI NG  THIS  FAN  CONT I NUED

These fans are also built to take care of the homeowner’s spot ventilation needs when the room is 
occupied. The basic fan models allow a choice of three speeds. When fans are equipped with the optional 
Multi-Speed module, these models increase to a maximum level of 150 CFM for the FV-1115VKL2 and 110 
CFM for the FV-0511VKSL2 and FV-0511VKL2 either when the switch is turned on or activated by the 
optional Condensation Sensor module or the optional Motion Sensor module.

A High/Low Delay Timer, located inside the fan unit, is utilized to return the fan back to the pre-set
continuous ventilation mode. The installer needs to consult with the homeowner for the desired
setting on the timer (0 - 60 minutes) and make the adjustments during the installation.

CustomVent Multi-Speed module (Lower Setting).   ASHRAE 62.2-2016

(sq.feet)

<  500

501-1000

38
53
68
83
98

113
128
143
158

45
60
75
90

105
120
135
150
165

53
68
83
98

113
128
143
158
173

60
75
90

105
120
135
150
165
180

Two Bedrooms Three Bedrooms Four Bedrooms

Five Bedrooms

DoC Responsible Party:

Panasonic Corporation of North America

Two Riverfront Plaza, Newark, NJ 07102

1-866-292-7299

Customer Call Support:

Risk of Fire: Type IC-Inherently Protected.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 

(1) This device may not cause harmful interference, and (2) this device must accept any interference 

received, including interference that may cause undesired operation.

D ESCRI PT I O N

These products are listed by UL under UL file No. E78414.

These products use a sirocco fan driven by a DC motor powered by an integral transformer. The motor is

designed to have long operating life, high dynamic response, higher speed ranges with saving energy.

The grille covering the fan body is a spring-loaded, quick remove type. A damper for preventing air counter

flow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level. The

FCC Note: This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against 

harmful interference in a residential installation. This equipment generates, uses and can radiate radio 

frequency energy and, if not installed and used in accordance with the instructions, may cause harmful 

interference to radio communications. However, there is no guarantee that interference will not occur in 

a particular installation. If this equipment does cause harmful interference to radio or television reception, 

which can be determined by turning this product on and off, the user is encouraged to try to correct the 

interference by one of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect equipment into outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

Warning: This equipment m us t be installed by qualified person in accordance with t he provided installation 

instructions; and all applicable codes and standards. Also, any changes or modifications not expressly 

approved by the party responsible for compliance could void the user’s authority to operate this equipment

lighting unit is an energy-saving LED lighting device that uses one 10W LED lamp and produces almost the 

same illumination as a standard 40W incandescent lamp. Night light feature consumes around 0.1 to 0.4 W.

module the fans are built to run continuously at a pre-set lower level (FV-0511VKSL2 and FV-0511VKL2:  
0,30,40, 50, 60, 70, 80, 90, 100 CFM; FV-1115VKL2: 0, 50, 60, 70, 80, 90, 100, 110, 120 CFM). The setting 
is dependent on the size of the house and the individual wishes of the homeowner. It is crucial that the
installer pre-set the lower setting during the installation. Please refer to the chart below and the 

switch indication on page 6. 

English

1001-1500

173

180

188

195

1501-2000

2001-5500
2501-3000

3001-3500
3501-4000

4001-4500
4501-5000

Содержание FV-0511VKL2

Страница 1: ...L2 Representative models 2 3 3 4 4 5 5 5 5 6 6 7 7 8 8 10 10 11 READ AND SAVE THESE INSTRUCTIONS Thank you for purchasing this Panasonic product Please read these instructions carefully before attempting to install operate or service the Panasonic product Please carefully read the GENERAL SAFETY INFORMATION Failure to comply with instructions could result in personal injury or property damage Plea...

Страница 2: ...contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Installation work and electrical wiring must be done by qualified person s in acc...

Страница 3: ...eed control device Solid state controls may cause harmonic distortion which can cause motor humming noise Follow all local electrical and safety codes as well as the National Electrical Code NEC and the Occupation Safety and Health Act OSHA Always disconnect the power source before working on or near the fan motor or junction box Protect the supply wiring from sharp edges oil grease hot surfaces c...

Страница 4: ...ty sirocco fan developed to reduce the noise level The FCC Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not insta...

Страница 5: ...5VKL2 10 1 4 260 5 7 8 151 5 7 8 148 13 330 7 1 2 190 1 1 4 30 4 1 2 114 1 1 2 37 3 7 8 100 12 304 3 3 8 86 13 1 4 15 1 2 336 394 16 1 2 18 3 4 419 480 21 1 4 23 1 2 540 597 3 3 8 86 6 5 8 169 10 1 4 261 13 330 3 7 8 100 3 7 8 100 1 8 3 4 5 2 FV 0511VKL2 FV 1115VKL2 Part name Blade Grille Part name No No 8 2 4 1 3 5 6 10 12 11 Motion sensor location FV MSVK1 not included Multi Speed module FV 0511...

Страница 6: ... the selected amount of time before returning to the lower speed setting chosen on the CFM dial Pick A Flow CFM Multi Speed Air volume CFM 50 110 110 130 150 0 0 0 0 0 0 40 40 40 60 60 60 40 60 60 80 80 80 40 70 80 100 100 100 40 70 80 100 100 110 120 30 30 30 50 50 50 40 50 50 70 70 70 40 70 70 90 90 90 40 70 90 100 110 110 Factory setting 20 minutes Delay Time position 0 Manual wall switch contr...

Страница 7: ...FV VS15VK1 Fan Hi Low speed Depend on FV VS15VK1 Time delay setting FV MSVK1 FV VS15VK1 FV MSVK1 Motion Sensor module turns the base fan on or boosts to higher speed when motion is detected when using in combination with the FV VS15VK1 The Motion Sensor is pre set to run for 20 minutes it will then re check for movement if detected the fan will run for another 20 minutes cycle The Motion Sensor de...

Страница 8: ...ast bracket to joists by drilling 2 tapping screws which have been fixed on it Fig 2 TM TM 3 Adjust the length of Flex Z Fast bracket as the spacing between joists and install to joists by drilling the other 2 tapping screws which have been fixed on it Fig 3 4 Remove junction box cover and secure conduit or stress relief to junction box knock out hole Fig 4 TM 6 Install the adaptor to Flex Z Fast ...

Страница 9: ...Secure machine screw M4X8 to the suitable hole and not touch the Flex Z Fast bracket Please fix the screw carefully to avoid screw slip teeth TM 9 Finish ceiling work Ceiling hole should be aligned with the inside edge of the flange Fig 7 CAUTION CAUTION 10 Insert the grille mounting spring on the wiring side into the slot and insert the plug connector into the housing of the lighting unit Fig 8 B...

Страница 10: ...g 11 2 Follow the step 1 4 5 7 on INSTALLATION NEW CONSTRUCTION Before connect the circular duct to the adaptor should pull down the circular duct from the ceiling Disconnect power source before working on unit 5 Follow the step 10 to 12 on INSTALLATION NEW CONSTRUCTION TM TM 3 Install the adaptor to Flex Z Fast bracket by using 2 self drilling screws Fig 12 4 Secure the fan body to Flex Z Fast br...

Страница 11: ...t into hot water Use non abrasive kitchen detergent wipe dry with clean cloth Fig 16 3 The grille should be dry after cleaning 4 Remove dust and dirt from fan body using a vacuum cleaner Fig 17 5 Using a cloth dampened with kitchen detergent remove any dirt from fan body Wipe dry with clean cloth Fig 18 6 Reinstall grille 1 Remove grille by pulling down one mounting spring Fig 14 then pull down th...

Страница 12: ...ment and absorbs sound Clamps plus mastic or approved foil faced tape at all flex joints Foil tape tightly covers all metal duct joints glue PVC joints Properly insulate the area around the fan to minimize building heat loss and gain Fig 19 Loose fill or batt insulation can be placed directly over the fan housing in the attic Our fans does not create excessive heat that is a common problem with re...

Отзывы: