30
Operating methods
Control panel
Child Lock button /
indicator
(
P.32
)
ECONAVI indicator
Air Volume button
/ indicator
Power Off / On button
“nanoe™” indicator
PM2.5 indicator
Clothes Refresh button /
indicator
(
P.32
)
Light sensor
Clean sign
Humidity sign
Humidifying indicator
Check indicator
ECONAVI indicator
●
The indicator is lit during ECONAVI operation.
(P.37)
(The indicator is lit when the air volume is set at
[
(Auto)] or [
(Quiet) ].)
●
ECONAVI operation can be turned off.
●
During operation, press
and
simultaneously and hold for 3 seconds. (ECONAVI
indicator is turned off.)
●
To restart ECONAVI operation, press the buttons
simultaneously and hold for 3 seconds again. (ECONAVI
indicator is lit.)
PM2.5 indicator
When the product detects PM2.5, the PM2.5 indicator
is lit and the clean sign blinks red. Then, the clean
sign changes from blinking to lit. (PM2.5 indicator is lit
when the product detects substances of the size of
2.5
μ
m or less, such as cigarette smoke or dust.)
Humidity sign
●
The sign indicates the status of ambient humidity.
[
(Low humidity) ] (red):
indicates the ambient humidity is low
(about 40 % or less).
[
(Moderate humidity) ] (green):
indicates the ambient humidity is moderate
(about 40 % to 60 %).
[
(High humidity) ] (red):
indicates the ambient humidity is high
(about 60 % or more).
Clean sign
The sign indicates the air pollution level detected by
dirt sensor. The sensitivity of the sensor can be
changed. (P.38 Q8)
(blue): indicates the air is clean.
(red-small): indicates the air is slightly dirty.
(red-large): indicates the air is dirty.
nanoe™ indicator
●
The indicator is lit when nanoe™ is generated.
●
nanoe™
operation can be turned off.
●
During operation, press
and
simultaneously and hold for 3 seconds. (The nanoe™
indicator is turned off.)
●
To restart nanoe™ operation, press the buttons and hold
for 3 seconds again. (The nanoe™ indicator is lit.)
Check indicator
When the abnormality occurs in the products, the
indicator is lit.
When the indicator is lit.
→
(P.41)
Light sensor
Detecting indoor brightness with the light sensor, the
product adjusts the brightness of indicators and the signs
of control panel and adjusts the air volume, automatically.
When the room becomes dark, for example during sleep,
the product operates "Sleep mode auto operation". (P.37)
(When the air volume is set at [
(High)] or
[
(Low)], the product does not adjust the air volume
even while "Sleep mode auto operation" is set.)