background image

Area Ionizer 

ER-X

 

SERIES

7

ORDER GUIDE

Heads

Head connection cable is not supplied with the head. Please order it separately.

Type

Appearance

Charge removal time  

(±1,000 V→±100 V)

Ion balance

Effective charge

removal width

Model No.

Spot type

0.3 sec. or less  

(Note 1),

0.5 sec. or less  

(Note 2)

±30 V or less

(Note 2, 3)

50 mm 

1.969 in

 

approx.

ER-X001

 

(Note 4)

Bar 

type

1 sec. or less  

(Note 2)

80 mm 

3.150 in

 

approx.

ER-X008

 

(Note 4)

High 

and low 

temperature 

resistant

ER-X008HC

 

(Note 5)

160 mm 

6.299 in

 

approx.

ER-X016

High 

and low 

temperature 

resistant

ER-X016HC

 

(Note 5)

320 mm 

12.598 in

 

approx.

ER-X032

High 

and low 

temperature 

resistant

ER-X032HC

 

(Note 5)

480 mm 

18.898 in

 

approx.

ER-X048

High 

and low 

temperature 

resistant

ER-X048HC

 

(Note 5)

640mm 

25.197 in

 

approx.

ER-X064

High 

and low 

temperature 

resistant

ER-X064HC

 

(Note 5)

Notes: 1) Typical value in condition of discharge distance 50 mm 

1.969 in

, center of the product, discharge frequency 50 Hz and air supply 60 ℓ/min. (0.3 MPa).

2)  Typical value in condition of discharge distance 100 mm 

3.937 in

 (

ER-X001

: 50 mm 

1.969 in

), center of the product, discharge frequency 50 Hz 

(

ER-X□HC

: 30 Hz) and no air supply.

3) 

4) 

 Ion balance refers to the average value of plus and minus. The specification value is the typical one in condition used when ambient temperature 

change is less than ±10 °C, ion balance is set after 30 minutes from the discharge start, the ion balance control function is set ON.

 The 

ER-X001

 and 

ER-X008

 must be combined with the new-type 

ER-XC02

 controller.

For the

 Identification of previous-type and new-type controllers and for the combination with the head

, refer to p.1

6

.

5)  The 

ER-X□HC

 high / low temperature resistant type head can be used under temperatures from -60 to +200 °C 

-76 to +392 °F

. Be sure to use this head 

in combination with the new-type controller, 

ER-XC02

For the

 Identification of previous-type and new-type controllers and for the combination with the head

, refer to p.1

6

.

Содержание ER-X Series

Страница 1: ...2022 7 Pulse AC Method The contents of this catalog are as of October 2017 For the latest information please visit our company website Area Ionizer ER XSERIES...

Страница 2: ...plying a compressed air source the ion volume increases providing an improved tact time for substrate ionization This makes the ER X suitable for applications such as electronic paper and thin film so...

Страница 3: ...es the amount of ions being generated which changes according to environmental factors and compensate for this deviation in the controller thus maintaining a highly stable ion balance as an original o...

Страница 4: ...simple needle replacement The removable discharge needle unit including a set of four needles substantially simplifies maintenance To remove the unit just slide it toward both ends as indicated by the...

Страница 5: ...e ion generation timing for the two heads to synchronize or inverse Error output changeover switch Set the error output condition to generation of abnormal discharge or generation of abnormal discharg...

Страница 6: ...h speed charge removal on a taping machine Prevention of part feeder clogging Charge removal of molded plastic components on a conveyor belt Removing dust during food product cup transport Airlesschar...

Страница 7: ...nce 50 mm 1 969 in center of the product discharge frequency 50 Hz and air supply 60 min 0 3 MPa 2 Typical value in condition of discharge distance 100 mm 3 937 in ER X001 50 mm 1 969 in center of the...

Страница 8: ...orming to CCC Length 2 m 6 562 ft CN ACKR C2 AC cable conforming to KTL Length 2 m 6 562 ft Discharge needle unit ER XANT For ER X016 X032 X048 X064 Note 2 Unit with replacement tungsten needles 1 pc...

Страница 9: ...e generation 0 01 ppm or less Note 2 Maximum air pressure 0 1 MPa Applicable fluid Air dried clean air Note 5 Operating altitude 2 000 m 6561 68 ft or less Note 6 Ambient temperature Head 60 to 200 C...

Страница 10: ...to 65 RH Storage 35 to 85 RH Voltage withstandability 1 000 V AC for one min between all supply terminals connected together and enclosure 500 V AC for on min between supply terminals and F G Insulati...

Страница 11: ...0 200 7 874 400 15 748 600 23 622 800 31 496 1 000 39 370 Charge removal distance L mm in Charge removal time sec 2 4 6 8 10 L CPM Center Common to ER X001 X008 ER X001 Charge removal field airless 50...

Страница 12: ...z 1 600 62 992 1 400 55 118 1 200 47 244 1 000 39 370 800 31 496 600 23 622 400 15 748 200 7 874 0 200 7 874 100 3 937 300 11 811 100 3 937 200 7 874 500 19 685 300 11 811 400 15 748 400 15 748 500 19...

Страница 13: ...W CPM Center 600 23 622 300 11 811 400 15 748 200 7 874 500 19 685 100 3 937 0 Charge removal width W mm in Charge removal distance L mm in 400 15 748 200 7 874 200 7 874 400 15 748 800 31 496 600 23...

Страница 14: ...1 sec 2 sec Charge removal field vertical direction 0 5 MPa 50 Hz 0 L W CPM Center 1 600 62 992 800 31 496 1 000 39 370 400 15 748 600 23 622 200 7 874 1 400 55 118 1 200 47 244 Charge removal width W...

Страница 15: ...ification of previous type and new type controllers and for the combination with the head refer to p 16 COM White COM IN Violet COM OUT Orange Alarm output Black Error output Pink Discharge control in...

Страница 16: ...rify that the supply voltage variation is within the rating In case using switching regulator be sure to connect F G terminal When connecting removing the head or performing wiring or inspection work...

Страница 17: ...ltage units 3 When fastening the high voltage unit using M6 screws fasten before connecting the head connection cable 4 Use M6 screws for the installation of the high voltage unit of the ER X001 5 The...

Страница 18: ...6 35 1 378 25 0 984 2 6 5 0 256 mounting holes 2 4 5 0 177 mounting holes 17 0 669 12 0 472 6 0 236 28 4 1 118 180 7 087 170 6 693 162 6 378 192 7 559 160 6 299 18 0 709 18 0 709 12 pin connector DIME...

Страница 19: ...0 874 5 3 0 209 L Model No Length L ER XCC2 2 000 78 740 ER XCC5 5 000 196 850 Length L ER XAPS EX AC adapter Optional 22 2 0 874 19 6 0 772 Cable 1 8 m 5 910 ft F G wire 3 7 m 12 139 ft AC cable 1 8...

Страница 20: ...e have obtained some intellectual properties such as patent rights with respect to such applications or that the described applications may not infringe any intellectual property rights such as patent...

Отзывы:

Похожие инструкции для ER-X Series