background image

18

Area Ionizer 

ER-X

SERIES

ER-X008/X016/X032/X048/X064

Head

ER-X008HC/X016HC/X032HC/X048HC/X064HC

Head

Model No.

A

B

C

D

(E)

ER-X008

40 

1.575

106 

4.173

138 

5.433

150 

5.906

163 

6.417

ER-X016

120 

4.724

194 

7.638

226 

8.898

238 

9.370

251 

9.882

ER-X032

280 

11.024

354 

13.937

386 

15.197

398 

15.669

411 

16.181

ER-X048

440 

17.323

514 

20.236

546 

21.496

558 

21.969

571 

22.480

ER-X064

600 

23.622

674 

26.535

706 

27.795

718 

28.268

731 

28.780

Model No.

A

B

C

D

(E)

ER-X008HC

40 

1.575

106 

4.173

138 

5.433

150 

5.906

163 

6.417

ER-X016HC

120 

4.724

194 

7.638

226 

8.898

238 

9.370

251 

9.882

ER-X032HC

280 

11.024

354 

13.937

386 

15.197

398 

15.669

411 

16.181

ER-X048HC

440 

17.323

514 

20.236

546 

21.496

558 

21.969

571 

22.480

ER-X064HC

600 

23.622

674 

26.535

706 

27.795

718 

28.268

731 

28.780

Model No.

(F)

ER-X016

159.6 

6.283

ER-X032

319.6 

12.583

ER-X048

479.6 

18.882

ER-X064

639.6 

25.181

6.2

0.244

22

0.866

18

0.709

ø6.9 

ø0.272

 high-voltage cable 0.5 m 

1.640 ft

Joint for ø6 

ø0.236

 air tube

Clean air outlet (4 points)

28.5

1.122

9.4

0.370

A

40

1.575

40

1.575

9.4

0.370

B

28.5

1.122

Head mounting bracket

Head mounting bracket

Discharge needle unit

30 

1.181

(E)

4.2

0.165

18

0.709

D

C

9.4 

0.370

Points of discharge

needle ion air outlet

2-ø6.5

ø0.256

9.5 

0.374

31

1.220

28 

1.102

5

0.197

6

0.236

10.5

0.413

38

1.496

35

1.378

(25 

0.984

)

2-ø6.5 

ø0.256

mounting holes

2-ø4.5 

ø0.177

mounting holes

17

0.669

ø12

ø0.472

6

0.236

28.4

1.118

180 

7.087

170 

6.693

162 

6.378

192 

7.559

160 

6.299

18

0.709

18

0.709

12-pin connector

DIMENSIONS (Unit: mm 

in

)

The CAD data can be downloaded from our website.

Mounting drawing with discharge part protective cover (ER-XACVR)

159.6 

6.283

(160 

6.299

)

(F) 

Discharge part protective cover

45.7

1.799

15.7 

0.618

18

0.709

25.4

1.000

18

0.709

Note: The 

ER-XACVR

 discharge part protective cover cannot be used on the 

ER-X008

 or  high and low temperature resistant type head 

ER-X□HC

.

Details of a head mounting bracket

4.2

0.165

9.4 

0.370

6.2

0.244

2-ø6.5

ø0.256

18

0.709

Details of a head mounting bracket

4.2

0.165

9.4 

0.370

6.2

0.244

2-ø6.5

ø0.256

18

0.709

6.2

0.244

Head mounting bracket

38

1.496

35

1.378

(25 

0.984

)

2-ø4.5 

ø0.177

mounting holes

18

0.709

1300

51.181

Allowable ambient temperature: -60 to +200 °C 

-76 to +392 °F

28.4 

1.118

30 

1.181

6

0.236

192 

7.559

162 

6.378

170 

6.693

10.5

0.413

Head mounting bracket

17

0.669

6

0.236

28.5

1.122

9.4

0.370

9.4

0.370

28.5

1.122

28 

1.102

5

0.197

Clean air outlet (4 points)

ø6.9 

ø0.272

 heat-resistant 

high-voltage cable (1.8 m 

5.906 ft

)

ø6 

ø0.236

-4 air tube joint (accessory)

18

0.709

22

0.866

ø12

ø0.472

(E)

D

C

40

1.575

40

1.575

31

1.220

9.5 

0.374

2-ø6.5 

ø0.256

mounting holes

A

B

Points of discharge

needle ion air outlet

Discharge needle unit

180 

7.087

160 

6.299

4.2

0.165

18

0.709

9.4 

0.370

2-ø6.5

ø0.256

12-pin connector

18

0.709

10

0.394

6.9

0.272

4

0.157

Содержание ER-X Series

Страница 1: ...2022 7 Pulse AC Method The contents of this catalog are as of October 2017 For the latest information please visit our company website Area Ionizer ER XSERIES...

Страница 2: ...plying a compressed air source the ion volume increases providing an improved tact time for substrate ionization This makes the ER X suitable for applications such as electronic paper and thin film so...

Страница 3: ...es the amount of ions being generated which changes according to environmental factors and compensate for this deviation in the controller thus maintaining a highly stable ion balance as an original o...

Страница 4: ...simple needle replacement The removable discharge needle unit including a set of four needles substantially simplifies maintenance To remove the unit just slide it toward both ends as indicated by the...

Страница 5: ...e ion generation timing for the two heads to synchronize or inverse Error output changeover switch Set the error output condition to generation of abnormal discharge or generation of abnormal discharg...

Страница 6: ...h speed charge removal on a taping machine Prevention of part feeder clogging Charge removal of molded plastic components on a conveyor belt Removing dust during food product cup transport Airlesschar...

Страница 7: ...nce 50 mm 1 969 in center of the product discharge frequency 50 Hz and air supply 60 min 0 3 MPa 2 Typical value in condition of discharge distance 100 mm 3 937 in ER X001 50 mm 1 969 in center of the...

Страница 8: ...orming to CCC Length 2 m 6 562 ft CN ACKR C2 AC cable conforming to KTL Length 2 m 6 562 ft Discharge needle unit ER XANT For ER X016 X032 X048 X064 Note 2 Unit with replacement tungsten needles 1 pc...

Страница 9: ...e generation 0 01 ppm or less Note 2 Maximum air pressure 0 1 MPa Applicable fluid Air dried clean air Note 5 Operating altitude 2 000 m 6561 68 ft or less Note 6 Ambient temperature Head 60 to 200 C...

Страница 10: ...to 65 RH Storage 35 to 85 RH Voltage withstandability 1 000 V AC for one min between all supply terminals connected together and enclosure 500 V AC for on min between supply terminals and F G Insulati...

Страница 11: ...0 200 7 874 400 15 748 600 23 622 800 31 496 1 000 39 370 Charge removal distance L mm in Charge removal time sec 2 4 6 8 10 L CPM Center Common to ER X001 X008 ER X001 Charge removal field airless 50...

Страница 12: ...z 1 600 62 992 1 400 55 118 1 200 47 244 1 000 39 370 800 31 496 600 23 622 400 15 748 200 7 874 0 200 7 874 100 3 937 300 11 811 100 3 937 200 7 874 500 19 685 300 11 811 400 15 748 400 15 748 500 19...

Страница 13: ...W CPM Center 600 23 622 300 11 811 400 15 748 200 7 874 500 19 685 100 3 937 0 Charge removal width W mm in Charge removal distance L mm in 400 15 748 200 7 874 200 7 874 400 15 748 800 31 496 600 23...

Страница 14: ...1 sec 2 sec Charge removal field vertical direction 0 5 MPa 50 Hz 0 L W CPM Center 1 600 62 992 800 31 496 1 000 39 370 400 15 748 600 23 622 200 7 874 1 400 55 118 1 200 47 244 Charge removal width W...

Страница 15: ...ification of previous type and new type controllers and for the combination with the head refer to p 16 COM White COM IN Violet COM OUT Orange Alarm output Black Error output Pink Discharge control in...

Страница 16: ...rify that the supply voltage variation is within the rating In case using switching regulator be sure to connect F G terminal When connecting removing the head or performing wiring or inspection work...

Страница 17: ...ltage units 3 When fastening the high voltage unit using M6 screws fasten before connecting the head connection cable 4 Use M6 screws for the installation of the high voltage unit of the ER X001 5 The...

Страница 18: ...6 35 1 378 25 0 984 2 6 5 0 256 mounting holes 2 4 5 0 177 mounting holes 17 0 669 12 0 472 6 0 236 28 4 1 118 180 7 087 170 6 693 162 6 378 192 7 559 160 6 299 18 0 709 18 0 709 12 pin connector DIME...

Страница 19: ...0 874 5 3 0 209 L Model No Length L ER XCC2 2 000 78 740 ER XCC5 5 000 196 850 Length L ER XAPS EX AC adapter Optional 22 2 0 874 19 6 0 772 Cable 1 8 m 5 910 ft F G wire 3 7 m 12 139 ft AC cable 1 8...

Страница 20: ...e have obtained some intellectual properties such as patent rights with respect to such applications or that the described applications may not infringe any intellectual property rights such as patent...

Отзывы:

Похожие инструкции для ER-X Series