ADJUSTMENT PROCEDURES
Issue 1
Section 7
MCUK010801C8
Revision 0
– 48 –
Service Manual
2.
Highlight CNTROL OUT and, using the left / right cursor keys, select ADAC/CH. Press ENTER.
3.
Holding down the Shift key, press F4. Select PROG CHARG-DAC DATA.
4.
Enter a value of 442.
5.
Disconnect VBAT by setting the BCVCU Voltage switch to OFF.
6.
Measure the voltage across the Test Battery terminals. If the voltage is within the range 4.2 V ±5 mV, proceed to step 11.
Otherwise, calculate the difference (DAC STEP) as follows:
difference = (measured voltage - 4.2 V) / 7.4 mV