TEST AND MEASUREMENT
MCUK001002C8
Section 6
Issue 1
Service Manual
– 51 –
Revision 0
Figure 6.27: Battery calibration 4
12. Set the BCVCU to 12 V.
Temperature Calibration
1.
Ensure that VBAT is set to 4.1 V. Check that EXT PWR and IGN on the Interface Box is set to OFF.
2.
Scroll up the menu until CONTROL OUT is highlighted. Using the left / right cursor keys, highlight AADC ON and then
press ENTER.
3.
Press F4 and select VIEW ADC LINES.
4.
Check the value for ADIN3 (BAT TEMP). If the value is outside the range 168 - 248, then there is a fault and further
investigation is required. Otherwise, subtract this value from the theoretical value of 208 and record the result for later use.
Figure 6.28: Temperature calibration 1
5.
Press ‘N’ in the {repeat yes/no box}, then press ENTER.
6.
Press F6. Scroll down and highlight TRIM OTHER. Press ENTER.
7.
Highlight BAT TEMP and press ENTER to select. Enter the value recorded in step 4.
Содержание EB-GD93
Страница 4: ...Issue 1 iv MCUK001002C8 Revision 0 Service Manual This page is left intentionally blank ...
Страница 6: ...Issue 1 Section MCUK001002C8 Revision 0 vi Service Manual This page is left intentionally blank ...
Страница 73: ... 5 8 7 5 06 0 8 6HFWLRQ VVXH 6HUYLFH 0DQXDO 5HYLVLRQ 5 8 7 5 06 0DLQ 3 RJLF ...
Страница 74: ... 5 8 7 5 06 0 8 6HFWLRQ VVXH 6HUYLFH 0DQXDO 5HYLVLRQ 0DLQ 3 5 6KHHW RI C A B ...
Страница 75: ... 5 8 7 5 06 0 8 6HFWLRQ VVXH 6HUYLFH 0DQXDO 5HYLVLRQ 0DLQ 3 5 6KHHW RI C A B ...
Страница 76: ...CIRCUIT DIAGRAMS MCUK001002C8 Section 8 Issue 1 Service Manual 71 Revision 0 8 4 Keypad PCB ...
Страница 77: ......
Страница 78: ... 287 5 06 0 8 6HFWLRQ VVXH 6HUYLFH 0DQXDO 5HYLVLRQ 287 5 06 0DLQ 3 A B C D E F 1 2 3 4 ...
Страница 79: ... 287 5 06 VVXH 6HFWLRQ 0 8 5HYLVLRQ 6HUYLFH 0DQXDO H SDG 3 A B C D 1 2 3 4 5 ...