TEST AND MEASUREMENT
Issue 1
Section 6
MCUK001002C8
Revision 0
– 32 –
Service Manual
295 °C ±5 °C for an application time of 120 seconds or less,
or:
395 °C ±5 °C for an application time of 30 seconds or less.
Removal and re-mounting of components should be performed only once at any component position.
Note:
To avoid land detachment, do NOT apply excessive force on the soldering iron when heating the board.
Ensure that the solder has melted sufficiently to allow component removal without damaging the board.
Re-flowing / Re-touching
1.
Re-touching by soldering iron:
HAKKO 928 soldering iron is recommended.
900S-T-B tip for thicker solder joints and 900M-T-LB tip for thinner solder joints are recommended
2.
Tip temperature/time
Normal pad : 325±10°C, less than five seconds
Large Pad : 400±10°C, less than five seconds
3.
Pressure at solder tip
· Weight of soldering iron, (50gm) + 100gm to 150gm
· Do not exert pressure in the horizontal direction
4.
Retouching small components
Pinch the component using two soldering irons and retouch within four seconds
6.3.
External Testing
6.3.1.
General Information
The handset can be connected to a compatible personal computer for electronic adjustment and fault diagnosis. This section
provides a description of the equipment required to perform those tasks.
Testing and adjustment of the handheld unit can be performed with the outer case in place and the cradle connected. For in-
depth fault finding the unit should first be disassembled, as detailed in Section 4, and then the PCB Repair Jig used to connect
the PCBs together externally as they would be found in normal use. Fault tracing can then be performed on the PCBs using
suitable test equipment, such as spectrum analysers and oscilloscopes.
The unit must now be tested and calibrated for both frequency bands (900 MHz and 1800 MHz).
6.3.2.
Jigs and Tools
Interface Box (Part No. IFB003 / IFB004)
The Interface box provides:
IFB003: Voltage regulation for +7.2 V, +5.6 V or 4.8 V DC outputs. The +7.2 V switch setting is used as a supply to Li-Ion type
batteries (compatible for other products), the 5.6 V switch setting is used for PCB testing and the 4.8 V switch setting is used
for testing the complete unit.
Interface Box IFB004 is a later version that pr4.8 V, +7.2V and +8.2 V DC outputs. It also allows selection of external
power via the Interface cable.
RS 232 interface. Ensures that the Unit Under Test is supplied with the correct signal levels and format.
Содержание EB-GD93
Страница 4: ...Issue 1 iv MCUK001002C8 Revision 0 Service Manual This page is left intentionally blank ...
Страница 6: ...Issue 1 Section MCUK001002C8 Revision 0 vi Service Manual This page is left intentionally blank ...
Страница 73: ... 5 8 7 5 06 0 8 6HFWLRQ VVXH 6HUYLFH 0DQXDO 5HYLVLRQ 5 8 7 5 06 0DLQ 3 RJLF ...
Страница 74: ... 5 8 7 5 06 0 8 6HFWLRQ VVXH 6HUYLFH 0DQXDO 5HYLVLRQ 0DLQ 3 5 6KHHW RI C A B ...
Страница 75: ... 5 8 7 5 06 0 8 6HFWLRQ VVXH 6HUYLFH 0DQXDO 5HYLVLRQ 0DLQ 3 5 6KHHW RI C A B ...
Страница 76: ...CIRCUIT DIAGRAMS MCUK001002C8 Section 8 Issue 1 Service Manual 71 Revision 0 8 4 Keypad PCB ...
Страница 77: ......
Страница 78: ... 287 5 06 0 8 6HFWLRQ VVXH 6HUYLFH 0DQXDO 5HYLVLRQ 287 5 06 0DLQ 3 A B C D E F 1 2 3 4 ...
Страница 79: ... 287 5 06 VVXH 6HFWLRQ 0 8 5HYLVLRQ 6HUYLFH 0DQXDO H SDG 3 A B C D 1 2 3 4 5 ...