TEST AND MEASUREMENT
Issue 1
Section 6
MCUK001002C8
Revision 0
– 54 –
Service Manual
Figure 6.33: Charging calibration 4
Current Charging ADC Calibration
It is important to monitor the current when charging the Li-ion battery, both to protect against over-current and to determine
when charging is complete. The telephone uses the VCC3 and MADC (ICHG) connections of OMEGA to measure charging
current as an amplified voltage across a sense resistor.
NOTE:
This calibration procedure MUST be carried out once Charging Voltage calibration has been completed.
1.
Press F4 and select VIEW ADC LINES. Read ADIN5 (CRG CURRENT) and record this value.
Figure 6.34: ADC Calibration
2.
If this value is outside the range 101 - 251, then there is a fault and further investigation is required. Otherwise, calculate
the difference between the recorded value and the theoretical value of 161. Record this value for use later.
3.
Press F6 and select TRIM OTHER. Select COMP OFFSET and enter the value recorded in step 2.
4.
Press F9. Wait for the prompt “Saving EV Trim data” to disappear, turn OFF the power supplies and disconnect the
telephone.
Содержание EB-GD93
Страница 4: ...Issue 1 iv MCUK001002C8 Revision 0 Service Manual This page is left intentionally blank ...
Страница 6: ...Issue 1 Section MCUK001002C8 Revision 0 vi Service Manual This page is left intentionally blank ...
Страница 73: ... 5 8 7 5 06 0 8 6HFWLRQ VVXH 6HUYLFH 0DQXDO 5HYLVLRQ 5 8 7 5 06 0DLQ 3 RJLF ...
Страница 74: ... 5 8 7 5 06 0 8 6HFWLRQ VVXH 6HUYLFH 0DQXDO 5HYLVLRQ 0DLQ 3 5 6KHHW RI C A B ...
Страница 75: ... 5 8 7 5 06 0 8 6HFWLRQ VVXH 6HUYLFH 0DQXDO 5HYLVLRQ 0DLQ 3 5 6KHHW RI C A B ...
Страница 76: ...CIRCUIT DIAGRAMS MCUK001002C8 Section 8 Issue 1 Service Manual 71 Revision 0 8 4 Keypad PCB ...
Страница 77: ......
Страница 78: ... 287 5 06 0 8 6HFWLRQ VVXH 6HUYLFH 0DQXDO 5HYLVLRQ 287 5 06 0DLQ 3 A B C D E F 1 2 3 4 ...
Страница 79: ... 287 5 06 VVXH 6HFWLRQ 0 8 5HYLVLRQ 6HUYLFH 0DQXDO H SDG 3 A B C D 1 2 3 4 5 ...