154
DP-8032/8025
2008
Ver.1.2
E5: System Error
Code
Function
Possible Cause(s)
E5- 05
Vp (+24V, Scanner)
1. SDR PCB connector disconnected.
2. SDR PCB defective.
3. SPC PCB connector disconnected.
4. SPC PCB defective.
5. LVPS defective.
E5- 11
Printer Engine
Communication Abnormal
1. SPC PCB connector disconnected.
2. SPC PCB defective.
3. SC PCB connector disconnected.
4. SC PCB defective.
E5- 12
Scanner Engine
Communication Abnormal
E5- 17
Scanner Synchronization
E5- 19
Scanner Line
Synchronization
E5- 22
Finisher communication
1. SPC PCB connector is disconnected (CN724).
2. SPC PCB is defective.
3. IPC PCB is disconnected.
4. IPC PCB is defective.
5. Finisher Interface Cable is disconnected.
6. OP LVPS connector is disconnected (CN64, 65, 66).
7. OP LVPS is defective.
8. DC PCB connector is disconnected (CN144).
9. Finisher is defective.
E5- 42
Total Counter Connection
1. Total Counter connector disconnected.
2. Total Counter defective.
3. SPC PCB connector disconnected.
4. SPC PCB defective.
E5- 60
Power Supply Cooling Fan
Motor Rotation
1. Cooling Fan connector disconnected.
2. Cooling Fan defective.
3. SPC PCB connector disconnected.
4. SPC PCB defective.
5. LVPS defective.
E7: Optional Unit Error (DA-FS300)
Code
Function
Possible Cause(s)
E7- 22
Finisher Damper Motor
1. Motor Connector disconnected.
2. Motor defective.
3. Home Position Sensor Connector disconnected.
4. Home Position Sensor defective.
5. Gear defective.
E7- 23
Finisher Staple Motor
1. Motor Connector disconnected.
2. Motor defective.
3. Home Position Sensor Connector disconnected.
4. Home Position Sensor defective.
5. Micro Switch Harness disconnected.
6. Micro Switch defective.
7. Solenoid Harness disconnected.
8. Solenoid defective.
9. Gear defective.
10. Motor wedged with a jammed Staple.
Содержание DP-8025
Страница 2: ...2 ...
Страница 3: ...3 ...
Страница 5: ...5 Hinweis Beispiel ...
Страница 9: ...9 ...
Страница 10: ...10 ...
Страница 11: ...11 ...
Страница 12: ...12 memo ...
Страница 368: ...DZSD001829 15 Panasonic Software Operating Instructions Network Firmware Update Tool for Service Technicians Version 3 ...
Страница 381: ...Network Firmware Update Tool LAN Page 14 13 Confirm the message in the text box and click OK to close the tool or ...
Страница 382: ...DZSD000965 18 Panasonic Software Operating Instructions Local Firmware Update Tool for Service Technicians Version 3 ...
Страница 397: ...Published in Japan ...