152
DP-8032/8025
2008
Ver.1.2
E2: Lift DC Motor Error
Code
Function
Possible Cause(s)
E2- 01
Lift Motor Rotation
(1st Paper Tray)
1. Level Sensor connector disconnected.
2. Level Sensor defective.
3. Lift Mechanism defective.
4. Lift Motor connector disconnected.
5. Lift Motor defective.
6. SPC PCB connector disconnected.
7. SPC PCB defective.
8. LVPS defective.
E2- 02
Lift Motor Rotation
(2nd Paper Tray)
1. Level Sensor connector disconnected.
2. Level Sensor defective.
3. Lift Mechanism defective.
4. Lift Motor connector disconnected.
5. Lift Motor defective.
6. SPC PCB connector disconnected.
7. SPC PCB defective.
8. CST2 PCB connector disconnected.
9. CST2 PCB defective.
10. LVPS defective.
E2- 03
E2- 04
Lift Motor Rotation
(3rd Paper Tray)
Lift Motor Rotation
(4th Paper Tray)
1. Level Sensor connector disconnected.
2. Level Sensor defective.
3. Lift Mechanism defective.
4. Lift Motor connector disconnected.
5. Lift Motor defective.
6. SPC PCB connector disconnected.
7. SPC PCB defective.
8. CST2 PCB connector disconnected.
9. CST2 PCB defective.
10. CST3 PCB connector disconnected.
11. CST3 PCB defective.
12. LVPS defective.
E2- 08
Sheet Bypass Initialization
1. Sensor connector disconnected.
2. Sensor defective.
3. SPC PCB connector disconnected.
4. SPC PCB defective.
5. LVPS defective.
E2- 10
System Console Drive Motor
Rotation
1. Drive Mechanism defective.
2. Drive Motor connector disconnected.
3. Drive Motor defective.
4. CST2 PCB connector disconnected.
5. CST3 PCB connector disconnected.
6. CST3 PCB defective.
7. LVPS connector disconnected.
8. LVPS defective.
9. SPC PCB connector disconnected.
10. SPC PCB defective.
Содержание DP-8025
Страница 2: ...2 ...
Страница 3: ...3 ...
Страница 5: ...5 Hinweis Beispiel ...
Страница 9: ...9 ...
Страница 10: ...10 ...
Страница 11: ...11 ...
Страница 12: ...12 memo ...
Страница 368: ...DZSD001829 15 Panasonic Software Operating Instructions Network Firmware Update Tool for Service Technicians Version 3 ...
Страница 381: ...Network Firmware Update Tool LAN Page 14 13 Confirm the message in the text box and click OK to close the tool or ...
Страница 382: ...DZSD000965 18 Panasonic Software Operating Instructions Local Firmware Update Tool for Service Technicians Version 3 ...
Страница 397: ...Published in Japan ...