163
UF-9000
JAN 2004
Ver. 1.0
DP-180/190
040 Flash Time
(PSTN)
5 = 50 ms
~
100 = 1000 ms
Selects the pause interval before activating the
Flash key.
(For Germany, Austria and Czech)
041 Pause Time
1 = 1 sec.
~
10 = 10 sec.
Selects the pause interval from 1 sec. ~ 10 sec. for
dialing through a switchboard or for international
calls.
042 Not Used
043 Redial Interval
0 = no waiting
~
15 = 15 minutes
Selects the redial interval from 0 to 15 minutes in 1
minute steps.
044 Redial Count
0 = no redial
~
15 = 15 times
0 ~ 9 (For Australia Only)
Selects the redial count from 0 to 15 times in 1 step
intervals.
Note:
In order to comply with the requirements TBR21
in the EC countries, do not select 15 times.
045 Ring Detect
Count
1 = 1 ring
~
9 = 9 rings
Selects the ring detection count from 1 to 9 rings in
1 ring step intervals.
046 On-Hook Time
0 = 0 sec.
~
90 = 90 sec.
Selects the on-hook time between sequential
communication calls in 1 second step intervals.
047 Response Wait
Interval
1 = 1 sec.
~
90 = 90 sec.
20 ~ 150 sec.
(For France Only)
Selects the waiting interval for the response after
completing the dialing.
048~
049
Not Used
050 Ring Detect Mode 1 = Normal
2 = Rough
Selects the quality of ringer detection. Use if the line
signal is out of regulation, set to "Rough" so that the
unit may detect the ringing signals.
051 Not Used
052 Pulse Rate
1 = 10 pps
2 = 20 pps
Selects the dial pulse rate 10/20 pps.
053~
054
Not Used
055 Busy Tone Check 1 = Off
2 = On
Selects whether to detect the Busy Tone.
056 Dial Tone Check
(Except for USA
and Canada)
1 = Off
2 = On
Selects whether to detect Dial Tone before dialing
the telephone number.
057 DC Loop Check
(Except for USA
and Canada)
1 = Off
2 = On
Selects whether the unit checks the DC Loop during
communication.
058 Comm. JRNL +
Image
1 = Off (without image)
2 = On (with image)
Selects whether the machine prints the COMM.
Journal with image.
059 Confidential RCV
Report
1 = Off (does not print out)
2 = On (prints out)
Selects whether the machine prints the Confidential
RCV Report.
060 Version
Indicates the Host software
version.
Function Parameter Table
No.
Parameter
Selections
Function
Содержание DP-180/190
Страница 48: ...48 UF 9000 JAN 2004 Ver 1 0 DP 180 190 20 Remove the LCD Module 127 ...
Страница 72: ...72 UF 9000 JAN 2004 Ver 1 0 DP 180 190 3 3 Preventive Maintenance Points ...
Страница 123: ...123 UF 9000 JAN 2004 Ver 1 0 DP 180 190 Sensor and Switch Location ...
Страница 169: ...169 UF 9000 JAN 2004 Ver 1 0 DP 180 190 6 3 Printer Receive Mechanism 6 3 1 Component Layout and Paper Path ...
Страница 264: ...264 UF 9000 JAN 2004 Ver 1 0 DP 180 190 memo ...
Страница 266: ...266 JAN 2004 Ver 1 0 UF 9000 DP 180 190 memo ...
Страница 267: ...DZSD001829 6 88 Software Operating Instructions Network Firmware Update Tool Service Tool Version 3 ...
Страница 281: ...DZSD000965 10 Panasonic Software Operating Instructions Local Firmware Update Tool Service Tool Version 3 ...
Страница 295: ...memo ...
Страница 296: ...DZZSM00249 ...