129
UF-9000
JAN 2004
Ver. 1.0
DP-180/190
496
XMT
C
CS of modem is not able to turn
ON.
FXB PCB is defective.
501
XMT/
RCV(V.34)
B
Remote unit does not have
compatible Modem.
502
XMT/
RCV(V.34)
B, C, D During reception, CD turned OFF
or continued ON for long time.
During communication, lost loop -
current.
Line is disconnected.
Transmitter is defective.
SC PCB or FXB PCB are defective.
503
XMT/
RCV(V.34)
B, C, D CS of modem is not able to turn
ON during training.
FXB PCB is defective.
Line is disconnected.
504
RCV/V.34
(Polling)
B
Polling is rejected from the remote
station.
No polling original is set.
505
XMT/V.34
(Polling)
B
Polling XMT is rejected.
No polling original is set.
540
XMT ECM
B
No response after transmitting 3rd
CTC or DCN received.
Incompatible interface.
541
XMT ECM
D
No response after transmitting 3rd
EOR or received DCN.
Line is faulty.
FXB PCB abnormal.
542
XMT ECM
D
No response to the 3rd RR
transmitted or received DCN.
Remote unit is abnormal.
543
XMT ECM
D
T5 timer (60 sec.) elapsed without
MCF.
Remote unit is abnormal.
544
XMT ECM
D
Stopped Transmission after EOR
Transmission.
Line is faulty.
FXB PCB abnormal.
550
RCV ECM
C
Timer between frames in phase C
has elapsed.
Defective remote station.
554
RCV ECM
D
Transmitted ERR after receiving
EOR.
Line is faulty.
555
RCV ECM
D
Transmitted PIN after receiving
EOR.
Line is faulty and Operator Call
requested by RX side.
570
RCV
B
Password or machine code did not
match during remote diagnostic
communication.
571
XMT
B
Remote unit did not have the
remote diagnostic function.
580
XMT
B
Sub-address transmission to a unit
that has their DIS bit 49 (NSF bit
155) OFF.
Sub-address transmission to a unit that
has no Sub-address function.
581
XMT
B
Sub-address Password
transmission to a unit that has their
DIS bit 50 (NSF bit 156) OFF.
Sub-address transmission to a unit that
has no Sub-address function.
582
XMT
B
Sub-address SEP (for Polling)
transmission to a unit that has their
DIS bit 47 (NSF bit 130) OFF.
Sub-address transmission to a unit that
has no Sub-address function.
601
XMT
ADF Door was opened during ADF
transmission.
623
XMT
A
No original was in the ADF. (Built-
in dialer engaged)
Operator removed the original from the
ADF after dialing was completed.
Original was not set properly in the ADF.
Fax Information Codes
Code
Mode
Phase
Description of Problem
Cause
Содержание DP-180/190
Страница 48: ...48 UF 9000 JAN 2004 Ver 1 0 DP 180 190 20 Remove the LCD Module 127 ...
Страница 72: ...72 UF 9000 JAN 2004 Ver 1 0 DP 180 190 3 3 Preventive Maintenance Points ...
Страница 123: ...123 UF 9000 JAN 2004 Ver 1 0 DP 180 190 Sensor and Switch Location ...
Страница 169: ...169 UF 9000 JAN 2004 Ver 1 0 DP 180 190 6 3 Printer Receive Mechanism 6 3 1 Component Layout and Paper Path ...
Страница 264: ...264 UF 9000 JAN 2004 Ver 1 0 DP 180 190 memo ...
Страница 266: ...266 JAN 2004 Ver 1 0 UF 9000 DP 180 190 memo ...
Страница 267: ...DZSD001829 6 88 Software Operating Instructions Network Firmware Update Tool Service Tool Version 3 ...
Страница 281: ...DZSD000965 10 Panasonic Software Operating Instructions Local Firmware Update Tool Service Tool Version 3 ...
Страница 295: ...memo ...
Страница 296: ...DZZSM00249 ...