162
UF-9000
JAN 2004
Ver. 1.0
DP-180/190
021 EP Tone
1 = Off (without EP Tone)
2 = On (with EP Tone)
Selects whether to add the echo protect tone on
V.29 mode.
(Used when Echo Suppression is disabled.)
On
: Add
Off
: Do not add
022 Signal Interval
1 = 100 ms
2 = 200 ms
3 = 500 ms
Selects the time interval between the receiving
signal and the transmitting signal.
023 TCF Check
1 = Normal (Short)
2 = Long
Selects the TCF check interval Long/Short
024 CED Frequency
1 = 1080 Hz (non ITU-T)
2 = 2100 Hz
Selects the CED frequency 2100/1080 Hz
025 COMM. Start-Up
1 = First
2 = Second
Selects the communication start-up condition (XMT
and Polling).
(Used when Echo Suppression is disabled.)
026 Non-Standard
1 = Off (Invalid)
2 = On (Valid)
Selects own mode (Panafax mode).
027 Short Protocol B
1 = Off (Invalid)
2 = On (Valid)
Selects the short protocol mode.
028 Short Protocol D
1 = Off (Invalid)
2 = On (Valid)
Selects the short protocol mode. When activated, it
allows the machine to automatically store the
modem speed for each Auto Dial Number.
029 Remote
Diagnostics
1 = Off (will not accept)
2 = On (accepts)
Selects whether the machine accepts Remote
Diagnostics from the service station.
030 CED & 300 bps
1 = 75 ms
2 = 1 sec
Selects the pause interval between the CED and
the 300 bps signal.
(Used when Echo Suppression is disabled.)
031 RTC = EOL x 12
1 = Off (EOLx6)
2 = On (EOLx12)
Selects the RTC signal, EOLx6 or EOLx12.
032 V34 TX Start
2400-33600bps
Selects the transmission modem start speed for
V.34 communication, 33600-2400 bps.
Press “V” or “/\ “ to select the symbol rate.
033 V34 RX Start
2400-33600bps
Selects the receiving modem start speed for V.34
communication, 33600-2400 bps.
Press “V” or “/\ “ to select the symbol rate.
034 V34 TX SR
2400-3429sr
Selects the transmission symbol rate for V.34, 3429/
3200/3000/2800/2400 sr.
Press “V” or “/\ “ to select the symbol rate.
035 V34 RX SR
2400-3429sr
Selects receiving symbol rate for V.34, 3429/3200/
3000/2800/2400 sr.
Press “V” or “/\ “ to select the symbol rate.
036 Not Used
037 Protocol Display
1 = Off (not displayed)
2 = On (displayed)
Selects whether to display the modem speed
during communication.
(Press the Job Status Key to display)
038 Not Used
039 Flash Time
5 = 50 ms
~
100 = 1000 ms
Selects the pause interval before activating the
Flash key.
Function Parameter Table
No.
Parameter
Selections
Function
Содержание DP-180/190
Страница 48: ...48 UF 9000 JAN 2004 Ver 1 0 DP 180 190 20 Remove the LCD Module 127 ...
Страница 72: ...72 UF 9000 JAN 2004 Ver 1 0 DP 180 190 3 3 Preventive Maintenance Points ...
Страница 123: ...123 UF 9000 JAN 2004 Ver 1 0 DP 180 190 Sensor and Switch Location ...
Страница 169: ...169 UF 9000 JAN 2004 Ver 1 0 DP 180 190 6 3 Printer Receive Mechanism 6 3 1 Component Layout and Paper Path ...
Страница 264: ...264 UF 9000 JAN 2004 Ver 1 0 DP 180 190 memo ...
Страница 266: ...266 JAN 2004 Ver 1 0 UF 9000 DP 180 190 memo ...
Страница 267: ...DZSD001829 6 88 Software Operating Instructions Network Firmware Update Tool Service Tool Version 3 ...
Страница 281: ...DZSD000965 10 Panasonic Software Operating Instructions Local Firmware Update Tool Service Tool Version 3 ...
Страница 295: ...memo ...
Страница 296: ...DZZSM00249 ...