15. Input the number of fifteen digits of QR code label (label
of the lower) pasted to OPU assay of the traverse unit,
and select "OK".
16. Take out the SD DIAG Card.
17. Detach the AC power supply code from the power supply
outlet, and select “OK”.
18. Turn off the switch of serial cable (RFKZ0139).
19. Connect the AC power supply code with the power supply
outlet, and select “OK”.
20. Adjust “DIAG” “SPEC” “LPC” by the automatic operation.
(It takes a few minutes.)
21. Set the DVD-RAM test disc (X5RAM-BPS), and select
“OK”.
22. Adjust “DISC” by the automatic operation.
23. Take out the DVD-RAM test disc (X5RAM-BPS).
24. Set the BD-ROM test disc (VFF0396), and select “OK”.
Содержание DMP-B100EB
Страница 10: ...10 4 1 Others Licenses ...
Страница 11: ...11 5 Location of Controls and Components B100P ...
Страница 12: ...12 B100PC ...
Страница 13: ...13 ...
Страница 23: ...23 9 Disassembly and Assembly Instructions 9 1 Disassembly Flow Chart ...
Страница 31: ...31 10 1 2 Checking and Repairing of Main P C B 2 ...