42
10 Measurements and Adjustments
10.1. Introduction
When servicing this unit, make sure to perform the adjustments necessary based on the part(s) replaced.
When trouble occurs, it is recommended to backup the Flash-rom data before disassembling the unit.
NOTICE: (When replacing the Lens unit, Master flange unit and MOS unit)
• When the MOS unit is unavoidably removed for Lens unit, Master flange unit and MOS unit replaced, an optical adjustment is
necessary after parts are exchanged.
• It is necessary to use the "DSC_Tilt" software to allow the "Optical tilt adjustment".
• The Adjustment software "DSC_Tilt" is available at "TSN Website".
NOTICE (When replacing the Flash ROM(IC6003) or Charging Control Microcomputer(IC1502))
When the Flash Rom or Charging Control Microcomputer is replaced, it is need to adjust the firmware of the Charging Control
Microcomputer to the one of the Flash ROM.
For details, refer to "10.3.2. Adjustment Specifications".
It may takes about 10 seconds. While doing the adjustment, don't turn the power off forcibly.
(It cause the Charging Control Microcomputer crush, then the camera can not turn on.)
NOTICE (When replacing the Main P.C.B.)
Number of necessary adjustment items decreases by copying the backup data to new Main P.C.B. when adjustment data in old
Main P.C.B. can be read by ROM_BACKUP "DSC
SD" in "10.2.2. Flash-Rom Data Backup".
For more details, please refer an item "MAIN PCB (to which the backup data was copied)" in the table of "10.3.2. Adjustment
Specifications".
IMPORTANT NOTICE (After replacing the Main P.C.B.)
After replacing the Main P.C.B., it is necessary to achieve adjustment.
10.2. Before Disassembling the unit
10.2.1. Initial Setting Release
The cameras specification are initially set in accordance with model suffix (such as EB, EG, GK, GC, and so on.).
Unless the initial setting is not released, an automatic alignment software in the camera is not able to be executed when the
alignment is carried out.
Note:
The initial setting should be again done after completing the alignment. Otherwise, the camera may not work properly.
Therefore as a warning, the camera display a warning symbol " ! " on the LCD monitor every time the camera is turned off.
Refer to the procedure described in "3.5.2. INITIAL SETTINGS" for details.
[How to Release the camera initial setting]
Preparation:
Attach the fully charged Battery, and insert the memory card (32MB or more).
Set the recording mode dial to PROGRAM AE mode.
Step 1. Temporary cancellation of "INITIAL SETTINGS":
While pressing the "RIGHT of Cursor button", MENU/SET button and DISPLAY button simultaneously, turn the Power on.
Step 2. Cancellation of "INITIAL SETTINGS":
Press PLAYBACK button to switch to the playback screen. (Keep pressing the button.)
Press " UP of Cursor button" additionally.
Turn the Power off. (The warning symbol " ! " is displayed on the LCD monitor.)
Содержание DMC-TZ80EB
Страница 17: ...17 ...
Страница 27: ...27 9 3 1 Removal of the Rear Case Unit Fig D1 ...
Страница 28: ...28 9 3 2 Removal of the Rear Operation P C B Unit Fig D2 9 3 3 Removal of the LCD Unit Fig D3 ...
Страница 29: ...29 Fig D4 9 3 4 Removal of the Main P C B Speaker Fig D5 ...
Страница 30: ...30 Fig D6 Fig D7 9 3 5 Removal of the Eye Sensor FPC Fig D8 ...
Страница 31: ...31 9 3 6 Removal of the Lens Unit Fig D9 9 3 7 Removal of the Top Case Unit Fig D10 ...
Страница 32: ...32 9 3 8 Removal of the LVF Unit Top P C B Unit Flash Unit Fig D11 Fig D12 ...
Страница 47: ...47 ...
Страница 48: ...48 ...
Страница 49: ...49 ...
Страница 60: ...60 ...