45
10.3.1.3. Execute Adjustment
1. Perform step "10.3.1.1." to "10.3.1.2.", to reset the OIS
flag status "F" (Set) to "0" (Reset).
2. Press DISPLAY button after Flag reset.
OIS Adjustment screen is displayed on the LCD panel.
(Refer to Fig.3-3)
3. Press the shutter button. The adjustment will start
automatically.
Fig. 3-3
4. When the adjustment is completed successfully,
adjustment report menu appears with Green OK on the
LCD monitor. (Refer to Fig.3-4)
Fig. 3-4
10.3.1.4. Attention point during Adjustment
1. Step "10.3.1.3." procedure shows OIS adjustment as an
example. To perform the adjustment, refer to the "10.3.2.
Adjustment Specifications" table which shows key point
for each adjustment.
2. Do not move the light box, the camera or the chart while
adjusting. If one of these is moved accidentally, start the
adjustment again.
3. Do not press any buttons/keys until the default menu
(Fig.3-5) is displayed on the LCD monitor. Otherwise,
adjustment data may not be stored properly.
4. If the adjustment is interrupted accidentally, the alignment
data may not be properly saved in the Flash-ROM.
Fig. 3-5
10.3.1.5. Finalizing the Adjustment
1. Several adjustment flags can be reset ("F" into "0") at the same time. In this case, when the adjustment has been completed,
the screen will change showing the adjustment for the next item until all reset items are completed.
Also, when the shutter button is pressed, the screen jump to the next adjustment item.
2. To cancel the adjustment mode while in the process of performing the adjustment, follow this procedures.
(1) Press "DISPLAY button.
(2) Press "RIGHT of Cursor button".
Note:
*.If adjustment is cancelled with above procedure, adjustment is not completed. Make sure to adjust it later.
Содержание DMC-TZ80EB
Страница 17: ...17 ...
Страница 27: ...27 9 3 1 Removal of the Rear Case Unit Fig D1 ...
Страница 28: ...28 9 3 2 Removal of the Rear Operation P C B Unit Fig D2 9 3 3 Removal of the LCD Unit Fig D3 ...
Страница 29: ...29 Fig D4 9 3 4 Removal of the Main P C B Speaker Fig D5 ...
Страница 30: ...30 Fig D6 Fig D7 9 3 5 Removal of the Eye Sensor FPC Fig D8 ...
Страница 31: ...31 9 3 6 Removal of the Lens Unit Fig D9 9 3 7 Removal of the Top Case Unit Fig D10 ...
Страница 32: ...32 9 3 8 Removal of the LVF Unit Top P C B Unit Flash Unit Fig D11 Fig D12 ...
Страница 47: ...47 ...
Страница 48: ...48 ...
Страница 49: ...49 ...
Страница 60: ...60 ...