3-10
Brightness Adjustment
Purpose:
To set the optimum EVF brightness level.
Symptom of Misadjustment:
The EVF picture will be too white or black.
Test Point
: ----------
Adjustment : VR903 (EVF C.B.A.)
Specification: Natural Gradation
INPUT
: Color Bar Chart
Mode
: CAMERA
Equipment
: Viewfinder
Adjustment Procedure:
1. Aim the camcorder at the color bar chart.
2. Adjust the BRIGHTNESS CONTROL (VR903) so that the
brightness in the Viewfinder becomes natural gradation.
Focus Adjustment
Purpose:
To set the optimum focus on the EVF picture.
Symptom of Misadjustment:
The EVF picture will be out of focus.
Test Point
: ----------
Adjustment : VR902 (EVF C.B.A.)
Specification: Optimum focus
INPUT
: Color Bar Standard Tape
Mode
: PB
Equipment
: Viewfinder
Adjustment Procedure:
1. Aim the camcorder at the gray scale chart.
2. Adjust the FOCUS CONTROL (VR902) to optimum focus
in the Viewfinder.