1-2
X-RADIATION (MODEL: A,
B)
WARNING :
1. The potential source of X-Radiation in EVF sets is the High
Voltage section and the picture tube.
2. When using a picture tube test jig for service, ensure that
jig is capable of handling 10 kV without causing X-Radiation.
NOTE :
It is important to use an accurate periodically calibrated
high voltage meter.
3. Measure the High Voltage. The meter (electrostatic type)
reading should indicate 2.2 kV
±
0.1 kV. If the meter indication
is out of tolerance, immediate service and correction is
required to prevent the possibility of premature component
failure. To prevent an X-Radiation possibility, it is essential
to use the specified picture tube.