44
Outdoor Unit Installation Guidelines
Where a wall or other obstacle is in the path of outdoor unit’s intake or exhaust airflow, follow the installation
guidelines below.
For any of the below installation patterns, the wall height on the exhaust side should be 1200 mm or less.
10.2.2 Install The Outdoor Unit
After selecting the best location, start installation
to Indoor/Outdoor Unit Installation Diagram.
1. Fix the unit on concrete or rigid frame firmly
and horizontally by bolt nut (ø10 mm).
2. When installing at roof, please consider strong
wind and earthquake.
Please fasten the installation stand firmly with
bolt or nails.
Model A
B
C
D
CU-3E23***,
CU-3RE18***
613 mm
131 mm
16 mm
360.5 mm
10.2.3 Connect The Piping
Remove the control board cover (resin) from the
unit by loosening three screws.
Connecting The Piping To Outdoor Unit
Decide piping length and then cut by using pipe
cutter. Remove burrs from cut edge. Make flare
after inserting the flare nut (locate at valve) onto
the copper pipe.
Align center of piping to valves and then tighten
with torque wrench to the specified torque as
stated in the table.
Do not over tighten, over tightening may cause gas leakage
Piping size
Torque
1/4" [6.35 mm]
[18 N•m (1.8 kgf•m)]
3/8" [9.52 mm]
[42 N•m (4.3 kgf•m)]
1/2" [12.7 mm]
[55 N•m (5.6 kgf•m)]
5/8" [15.88 mm]
[65 N•m (6.6 kgf•m)]
3/4" [19.05 mm]
[100 N•m (10.2 kgf•m)]
More than 100
w
e
i
v
p
o
T
w
e
i
v
e
d
i
S
1200
or
less
More than 1000
More than 100
More than 1000
More than 100
More than 300
More
than 100
More than 1000
More than 100
Top view
Unit : mm
Wall facing one side
Wall facing two side
Wall facing three side
A
B
C
D
A
B
C
Screw
Screw
Control Board Cover (resin)
Flare Nut
Torque Wrench for
Flare Nut
(Connection Pipe)
(Connection Pipe)
Torque Wrench for
Flare Nut
Liquid side
Gas side
Flare Nut
Applicable to
Liquid and Gas side of
CS-ME5***
CS-E7***
CS-E9***
CS-E12***
CS-E15***
CS-E18***
CS-E21***
CS-XE7***
CS-XE9***
CS-XE12***
CS-XE18***
CS-MRE5***
CS-MRE7***
Liquid size of
CS-E21***
CS-MTZ5***
CS-MTZ7***
CS-RE9***
CS-RE12***
CS-RE15***
CS-RE18***
CS-MZ5***
CS-Z7***
CS-Z9***
CS-Z12***
CS-Z15***
CS-Z18***
CS-TZ9***
CS-TZ12***
CS-TZ15***
CS-TZ18***
CS-XE7***
CS-XE9***
CS-XE12***
CS-XE18***
CS-XZ7***
CS-XZ9***
CS-XZ12***
CS-XZ18***
Female side
Male side
Torque Wrench for Flare Nut
and Pipe Size Expander
Packing
Pipe Size
Expander
Flare Nut
(Connection Pipe)
Liquid side
Gas side
Applicable to
Gas side of
CS-E21***
Female side
Male side
Содержание CU-2E18SBE
Страница 35: ...8 8 4 CPU U Printed d Circuit Board 35...
Страница 61: ...61...
Страница 62: ...62...