4 REMOTE CONTROL RECEIVING SOUND OFF/ON MODE
The Remote Control Receiving Sound OFF/ON Mode will be activated if the Auto OFF/ON button is pressed
continuously for more than 16 seconds (4 “beep” sounds will occur at 16th seconds to identify the Remote
Control Receiving Sound Off/On Mode is in standby condition) and press “AC Reset” button at remote
control.
Press “Auto OFF/ON button” to toggle remote control receiving sound.
o
Short “beep”: Turn OFF remote control receiving sound.
o
Long “beep”: Turn ON remote control receiving sound.
After Auto OFF/ON Button is pressed, the 20 seconds counter for Remote Control Receiving Sound OFF/ON
Mode is restarted.
17.2 Heat Only Operation
17.2.1 How
to
Activate/Deactivate Heat only Operation
Use remote controller to set heating only operation. When the unit in standby mode, follow the steps below:
a) Press continuously for more than 5 seconds to enter special setting mode.
b) Press
to choose function 61, and then press
or
to set “01”. (To enable the “Heat Only” mode)
or “00” (To disable the “Heat Only” mode).
c) Press
to activate “Heating only operation” or deactivate “Heating only operation”.
17.2.2 Operation
mode
during Heating Only Operation
The table below shows the operation mode comparison when Heating Only Operation Mode Activated and
Deactivated.
Operation Mode
Heating Only Operation Mode Activated
Heating Only Operation Mode Deactivated
AUTO
After 30s sampling, regardless of the indoor intake or
outdoor intake temperature judgment, the unit will run
Heating operation.
After 30s sampling, the unit will judge the operation
mode base on remote controller temperature setting
and Indoor Intake Sensor (New Auto Mode) or
Outdoor Intake Sensor (Old Auto Mode).
HEAT
The unit will run Heating operation.
The unit will run Heating operation.
COOL
The unit will stop and Power LED blinking.
The unit will run Cooling operation.
DRY
The unit will stop and Power LED blinking.
The unit will run Cooling Dry operation.
NANOE Stand-alone
The unit will stop and Power LED blinking.
The unit will run Nanoe Stand-alone operation.
Force Cooling
The unit will run Force Cooling Operation for
X_CTRYTM [15] minutes
The unit will run Force Cooling operation.
Force Heating
The unit will run Force Heating operation.
The unit will run Force Heating operation.
AUTO (with Timer)
The unit will turn ON by the timer and run Auto
Operation. After 30s sampling, regardless of the
indoor intake or outdoor intake temperature judgment,
the unit will run Heating operation.
The unit will turn ON by the timer and run Auto
Operation. After 30s sampling, the unit will judge the
operation mode base on remote controller
temperature setting and Indoor Intake Sensor (New
Auto Mode) or Outdoor Intake Sensor (Old Auto
Mode).
HEAT (with Timer)
The unit will turn ON by the timer and run Heating
Operation.
The unit will turn ON by the timer and run Heating
Operation.
COOL (with Timer)
The unit will not turn ON by the timer. Power LED
blinking.
The unit will turn ON by the timer and run Cooling
Operation.
DRY (with Timer)
The unit will not turn ON by the timer. Power LED
blinking.
The unit will turn ON by the timer and run Cooling Dry
Operation.
Cooling Test Mode
The unit will stop and Power LED blinking.
The unit will operate according to specify Cooling test
mode operation parameter.
Heating Test Mode
The unit will operate according to specify Heating test
mode operation parameter.
The unit will operate according to specify Heating test
mode operation parameter.
SET
T 5secs
Special setting mode
(Function
no.)
(Options)
Activate or deactivate
“
Heating only