137
21.2 Heat Mode Outdoor Air Temperature Characteristic
Condition
-
Indoor room temperature: 20°C Dry Bulb/ -°C Wet Bulb
-
Unit setting: Standard piping length, forced heating at 30°C, Hi fan
-
Compressor frequency: Rated for Heating operation
-
Piping length: 5m
-
Voltage:
230V
21.2.1 CS-Z25UFEAW CU-Z25UBEA
Indoor Discharg
e
Air Temperature (°
C)
Indoor Discharg
e
Air Temperature (°
C)
Outdoor Air Temperature (°C)
Outdoor Air Temperature (°C)
Outdoor Air Temperature (°C)
High
Pressure (MPa)
Current (A)
1.00
2.00
3.00
4.00
5.00
6.00
1.4
1.6
1.8
2.0
2.2
2.4
2.6
2.8
20
24
28
32
36
40
44
-20
-15
-10
-5
0
5
10
15
-20
-15
-10
-5
0
5
10
15
-20
-15
-10
-5
0
5
10
15
Outdoor Air
Temperature (°C)
-15
-10
-7
2
33.17
33.97
35.51
38.68
7
39.45
12
39.89
Indoor Discharge
Air Temperature (°C)
Outdoor Air
Temperature (°C)
-15
-10
-7
2
1.77
2.07
2.41
3.12
7
3.50
12
3.71
Current
(A)
Outdoor Air
Temperature (°C)
-15
-10
-7
2
1.72
1.84
1.93
2.21
7
2.43
12
2.61
High Pressure
(MPa)