81
To limit set temperature range for iCOMFORT, COOL & DRY mode.
o
Press “Set” button by using pointer.
o
Press TEMP increment or decrement button to choose No. 3.
o
Press Timer increment or decrement button to select desired temperature low limit of set temperature for
iCOMFORT, COOL & DRY mode.
iCOMFiAUTO-XHEATCOOLDRYFAN
F
SHOWER
DIRECT
AM
PM
AM
ON
OFF
PM
Memorize new
Low2 range
Normal display mode
Press
SW to enter customer zone &
Press
SW’s to choose function 3
Press
SW to comfirm selection
Use
SW or
SW to change Low2 range
SET
i) Display latest set temp (Low2).
ii) After reset, Low2 = 16°C (by default)
Range = 16°C ~ [High2]
No code transmission
o
Press Timer Set button to confirm low limit selection.
o
Press TEMP increment or decrement button to choose No. 4.
o
Press Timer decrement or increment button to select desired temperature high limit of set temperature for
iCOMFORT, COOL & DRY mode.
iCOMFiAUTO-XHEATCOOLDRYFAN
F
SHOWER
DIRECT
AM
PM
AM
ON
OFF
PM
Memorize new
High2
range
Normal display mode
Press
SW to enter customer zone &
Press
SW’s to choose function 4
Press
SW to comfirm selection
Use
SW or
SW to change High2 range
SET
i) Display latest set temp (High2).
ii) After reset, High2 = 30°C (by default)
Range = [Low2] ~ 30°C
No code transmission
o
Press Timer Set button to confirm high limit selection.
o
LCD returns to original display if remote control does not operate for 30 seconds or press Timer Cancel
button.