15
Model
Indoor
CS-VU18SKQ
Outdoor
CU-VU18SKQ
Refrigeration
Cycle
Control Device
Expansion Valve
Refrigerant Oil
cm
3
FW50S (450)
Refrigerant Type
g (oz)
R32, 1.00k (35.3)
Dimension
Height (I/D / O/D)
mm (inch)
280 (11-1/32) / 619 (24-3/8)
Width (I/D / O/D)
mm (inch)
950 (37-13/32) / 824 (32-15/32)
Depth (I/D / O/D)
mm (inch)
318 (12-17/32) / 299 (11-25/32)
Weight
Net (I/D / O/D)
kg (lb)
13 (29) / 33 (73)
Piping
Pipe Diameter (Liquid / Gas)
mm (inch)
6.35 (1/4) / 12.70 (1/2)
Standard length
m (ft)
5.0 (16.4)
Length range (min – max)
m (ft)
3 (9.8) ~ 30 (98.4)
I/D & O/D Height different
m (ft)
20 (65.6)
Additional Gas Amount
g/m (oz/ft)
15 (0.2)
Length for Additional Gas
m (ft)
10 (32.8)
Drain Hose
Inner Diameter
mm
16.2
Length
mm
550
Indoor Heat
Exchanger
Fin Material
Aluminium (Pre Coated)
Fin Type
Slit Fin
Row × Stage × FPI
2 × 15 × 21
Size (W × H × L)
mm
675 × 315 × 25.4
Outdoor
Heat
Exchanger
Fin Material
Aluminium (Blue Coated)
Fin Type
Slit Fin
Row × Stage × FPI
2 × 28 × 17
Size (W × H × L)
mm
25.4 × 588 × 775.4:795.4
Air Filter
Material
Polypropelene
Type
One-touch
Power Supply
Outdoor
Power Supply Cord
A
-
Thermostat
-
Protection Device
-
Dry Bulb
Wet Bulb
Indoor Operation Range
Maximum °C
32
23
Minimum °C
16
11
Outdoor Operation Range
Maximum °C
43
26
Minimum °C
16
11
1.
Cooling capacities are based on indoor temperature of 27°C DRY BULB (80.6°F DRY BULB), 19.0°C WET BULB (66°F WET BULB) and
outdoor air temperature of 35°C DRY BULB (95°F DRY BULB), 24°C WET BULB (75.2°F WET BULB).